Dipstick measurements of urine specific gravity are unreliable
نویسندگان
چکیده
منابع مشابه
Dipstick measurements of urine specific gravity
Aim—To evaluate the reliability of dipstick measurements of urine specific gravity (U-SG). Methods—Fresh urine specimens were tested for urine pH and osmolality (U-pH, U-Osm) by a pH meter and an osmometer, and for U-SG by three diVerent methods (refractometry, automatic readout of a dipstick (Clinitek-50), and (visual) change of colour of the dipstick). Results—The correlations between the vis...
متن کاملA discrepant urine specific gravity.
A 21-year-old man presented after being struck by a car and underwent a computed tomography scan of the chest and spine. Three hours later, his clear yellow urine sample was sent to the laboratory. A routine urinalysis with the Roche Urisys® 2400 indicated the specific gravity (SG) as a flag, i.e., an error for SG. A manual repeat of the SG measurement was also not readable by refractometer (no...
متن کاملUrine Dipstick Analysis
All samples should be midstream and collected in a clean sterile container. Suprapubic aspiration or fresh catheter samples are ideal, but not always practical. The gold standard method of testing is to remove a small volume of urine from the sterile container with a fresh sterile syringe, and then apply the removed urine to the dipstick. In this way, the remainder of the collected sample conte...
متن کاملA dipstick test combined with urine specific gravity improved the accuracy of proteinuria determination in pregnancy screening.
Proteinuria screening using a semi-quantitative dipstick test of the spot urine in antenatal clinic is known to have high false-positive rates. The aim of this study was to assess availability of a dipstick test combined with the urine specific gravity for the determination of pathological proteinuria. A dipstick test was performed on 582 urine samples obtained from 283 pregnant women comprisin...
متن کاملIntrasubject variation of creatinine and specific gravity measurements in consecutive urine specimens of heroin users.
116 CLINICAL CHEMISTRY, Vol. 41, No. 1, 1995 drugs in full-scan and selected.ion monitoring modes. Clin Chem 1994;40:216-20. 2. Doolittle MH, Lincoln K, Graves SW. Unexplained increase in serum digoxin: case report. Clin Chem 1994;40:487-92. 3. Critchfield GC, Wilkins DG, Loughmiller DL, Davis BW, Rollins DE. Antibody-mediated interference of a homogeneous immunoassay. J Anal Toxicol 1993;17:69...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Archives of Disease in Childhood
سال: 2001
ISSN: 0003-9888