Diffusivity Measurements of Human Methemoglobin

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diffusivity Measurements of Human Methemoglobin

Experimental measurements of the diffusion coefficient of human methemoglobin were made at 25 degrees C with a modified Stokes diaphragm diffusion cell. A Millipore filter was used in place of the ordinary fritted disc to facilitate rapid achievement of steady state in the diaphragm. Methemoglobin concentrations varied from approximately 5 g/100 ml to 30 g/100 ml. The diffusion coefficient in t...

متن کامل

[Regulation of methemoglobin reduction in human erythrocytes].

The regulation of methemoglobin reduction in human erythrocytes was studied in vitro in association with glycolytic reactions, by using hemolysates prepared from the nitrate-treated eryth rocytes. The results obtained are as follows; 1) The addition of cytochrome b5 to the reaction mixture containing fructose 1,6-diphosphate as the substrate for glycolysis caused a marked increase in...

متن کامل

Evidence for nonequivalent binding sitesin human methemoglobin.

On the basis of nuclear magnetic resonance spectra, Davis, Charachc, and Ho (1) have recently suggested that the heme groups of the a! and /3 methemoglobin chains are not equivalent. Gibson, Parkhurst, and Geraci (2) have reported biphasic kinetics for the reaction of methemoglobin with a variety of iron-coordinating ligands. These results were also explained assuming nonequivalent heme groups....

متن کامل

Methemoglobin Formation in Human Blood by Cobalt

Although the erythropoietic effect of cobalt has been amply demonstrated in experimental animals (1-3), in normal human beings (4, 5), and in certain types of anemia (4, 6-8), the mechanism of this increased blood formation has not been elucidated. No evidence has been adduced that administration of cobalt causes a decrease in oxygen capacity (9) or alters the oxygen dissociation curve (10, 11)...

متن کامل

Measurements of surface diffusivity and coarsening during pulsed laser deposition.

Pulsed laser deposition (PLD) of homoepitaxial SrTiO(3) 001 was studied with in situ x-ray specular reflectivity and surface diffuse x-ray scattering. Unlike prior reflectivity-based studies, these measurements access both time and length scales of the evolution of the surface morphology during growth. In particular, we show that this technique allows direct measurements of the diffusivity for ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of General Physiology

سال: 1966

ISSN: 1540-7748,0022-1295

DOI: 10.1085/jgp.49.4.681