منابع مشابه
Diffusion-Weighted Imaging and Diffusion Tensor Imaging
Assessment of the integrity of the articular cartilage is considered key for the early diagnosis of osteoarthritis (OA). Diffusion-weighted imaging and diffusion tensor imaging have potential as biomarkers for cartilage composition and structure. The value of diffusion to detect compositional and structural changes in the cartilage matrix has been shown in ex vivo experiments for several years....
متن کاملPropagation Framework for Diffusion Tensor Imaging via Diffusion Tensor Error Propagation Framework for Diffusion Tensor Imaging via Diffusion Tensor Representations
This preprint is made available because the published work cited below had several infelicities due to production error, i.e., awkward layout of equations and font styles. The conversion from the Words document here to IEEE TMI format was a mess. Abstract An analytical framework of error propagation for diffusion tensor imaging (DTI) is presented. Using this framework, any uncertainty of intere...
متن کاملRegional distribution of measurement error in diffusion tensor imaging.
The characterization of measurement error is critical in assessing the significance of diffusion tensor imaging (DTI) findings in longitudinal and cohort studies of psychiatric disorders. We studied 20 healthy volunteers, each one scanned twice (average interval between scans of 51 +/- 46.8 days) with a single shot echo planar DTI technique. Intersession variability for fractional anisotropy (F...
متن کاملSpinal Diffusion Tensor Imaging
PHILIPP HENDRIX, CHRISTOPH J. GRIESSENAUER, JULIEN COHEN-ADAD, SHANMUGANATHAN RAJASEKARAN, KEITH A. CAULEY, MOHAMMADALI M. SHOJA, PARHAM PEZESHK, AND R. SHANE TUBBS Department of Neurosurgery, University of Alabama at Birmingham, Birmingham, Alabama Department of Biomedical Engineering, Ecole Polytechnique de Montreal, Quebec, Canada Department of Orthopaedic and Spine Surgery, Ganga Hospital, ...
متن کاملNerve Diffusion Tensor Imaging
Diffusion tensor imaging (DTI) is a magnetic resonance imaging technique that in vivo visualises random translational movement of water molecules. DTI has inherent difficulties with low signal-to-noise ratio, sensitivity to patient motion, field inhomogeneities and fast T2 relaxation. It has been used in the central nervous system, although it has not been assessed in the peripheral nervous sys...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: NMR in Biomedicine
سال: 2019
ISSN: 0952-3480,1099-1492
DOI: 10.1002/nbm.4066