Diffractive molecular-orbital tomography

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diffractive molecular orbital tomography

High harmonic generation in the interaction of femtosecond lasers with atoms and molecules opens the path to molecular orbital tomography and to probe the electronic dynamics with attosecondÅngström resolutions. Molecular orbital tomography requires both the amplitude and phase of the high harmonics. Yet the measurement of phases requires sophisticated techniques and represents formidable chall...

متن کامل

Coulomb-corrected molecular orbital tomography of nitrogen

High-order harmonic generation (HHG) from aligned molecules has provided a promising way to probe the molecular orbital with an Ångström resolution. This method, usually called molecular orbital tomography (MOT) replies on a simple assumption of the plane-wave approximation (PW), which has long been questioned due to that PW approximation is known to be valid in the keV energy region. However, ...

متن کامل

Molecular orbital tomography from multi-channel harmonic emission in N2

High-order harmonic generation in aligned molecules can be used as an ultrafast probe of molecular structure and dynamics. By characterizing the emitted signal, one can retrieve information about electronic and nuclear dynamics occurring in the molecule at the attosecond timescale. In this paper, we discuss the theoretical and experimental aspects of molecular orbital tomography in N2 and inves...

متن کامل

Computed tomography of orbital myositis.

The computed tomographic (CT) scans of 11 consecutive patients with orbital myositis were reviewed to better characterize the CT appearance of this condition. The findings in this series differed from those of previous reports in several ways. Multiple muscle involvement predominated. Bilateral involvement was more frequent than previously reported. Enlargement of the tendon as well as the musc...

متن کامل

Computer assisted tomography in orbital disease.

Computer assisted tomography (CAT) in the transverse axial plane, a fundamentally new method of x-ray diagnosis, was developed from I967 to 1972 by G. N. Hounsfield (I973) at the Central Research Laboratories of E.M.I. Ltd. Clinical evaluation of this technique by J. Ambrose (I973) at Atkinson Morley's Hospital has indicated the enormous value of the investigation in patients with intracranial ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Physical Review A

سال: 2017

ISSN: 2469-9926,2469-9934

DOI: 10.1103/physreva.95.033420