Dielectric and Flash-over Characteristics of the ±1100kV Valve Side Converter Transformer Bushing with SF6 Gas Insulation

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of Moisture in Transformer Insulation Using Dielectric Frequency Response Analysis by Heuristic Algorithms

Transformers are one of the most valuable assets of power systems. Maintenance and condition assessment of transformers has become one of the concerns of researchers due to huge number of transformers has been approached to the end of their lifetimes. Transformer’s lifetime depends on the life of its insulation and the insulation’s life is strongly influenced by its moisture attraction as well....

متن کامل

Analysis of the Root Causes of Transformer Bushing Failures

This paper presents the results of a comprehensive investigation of five blackouts that occurred on 28 August to 8 September 2011 due to bushing failures of the 132/33 kV, 125 MVA transformers at JBB Ali Grid station. The investigation aims to explore the root causes of the bushing failures and come up with recommendations that help in rectifying the problem and avoiding the reoccurrence of sim...

متن کامل

the evaluation of language related engagment and task related engagment with the purpose of investigating the effect of metatalk and task typology

abstract while task-based instruction is considered as the most effective way to learn a language in the related literature, it is oversimplified on various grounds. different variables may affect how students are engaged with not only the language but also with the task itself. the present study was conducted to investigate language and task related engagement on the basis of the task typolog...

15 صفحه اول

Simulation of Transformer With Aging Insulation and Incipient Faults

The development of the transformer insulation failure undergoes three stages: insulation aging, incipient faults and a short circuit. This paper presents a complete scheme to simulate single-phase transformers with insulation deterioration and arcing phenomena i.e. in the first two stages. The approach incorporates Transmission Line Methods (TLM), Jiles-Atherton Hysteretic Model, Composite Cass...

متن کامل

Effect of Stress on Transformer Insulation

Power transformers use Kraft paper as insulation in the electrical windings present in the core, which is immersed in oil. In service, the temperature of the windings of core will go to 75C to 85C. If the transformer is over loaded, then the temperature can exceed upto 100°C causing the cellulose chains in the paper to cleave at an accelerated rate, which results in the degradation of mechanica...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Physics: Conference Series

سال: 2021

ISSN: 1742-6588,1742-6596

DOI: 10.1088/1742-6596/1948/1/012080