Diagnostic value of sequential readings with the Minolta transcutaneous bilirubinometer in normal and low-birthweight infants.

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcutaneous Bilirubinometer

Neonatal jaundice occurs in nearly 70% of term and 80% of preterm babies. Management of jaundiced neonates often requires measurement of total serum bilirubin (TSB). Total serum bilirubin (TSB) is commonly determined by spectro-photometric methods by analyzing plasma or serum sample. Such techniques require drawing of blood causing pain and trauma to the neonate. In addition, there is a wide ra...

متن کامل

Normal ranges of T4 screening values in low birthweight infants.

Thyroxine (T4) screening values in infants of low birthweight in relation to birthweight and gestational age are reported. There were 86 healthy infants of low birthweight (group 1), and 29 preterm infants with respiratory distress syndrome (group 2). All the group 2 infants and 36% of those in group 1 had a T4 screening value below the cut-off point (-2.1 SD). In group 1 there was a significan...

متن کامل

study the effects of low level laser diode on no production and healing of diabetic and cortisone acetate and normal wounded sd rats

nitric oxide (no) is a small molecule synthesized by most of mammalian cells with diverse biological activities including vasodilatation, host defense and wound healing. impaired wound healing is a common occurrence among diabetics and patients receiving glucocorticoid therapy. on the other hand the application of laser in biomedical area have been increased. thus, the current studies were desi...

15 صفحه اول

Evaluation of a new transcutaneous bilirubinometer.

OBJECTIVE The objective of this study was to evaluate the Minolta/Hill-Rom Air-Shields Transcutaneous Jaundice Meter model JM-103. METHODS We studied a convenience sample of 849 newborns > or =35 weeks of gestation in 3 hospitals. These infants had total serum bilirubin (TSB) levels measured on clinical indication, and transcutaneous bilirubin (TcB) levels were obtained within 1 hour of the T...

متن کامل

Screening for Hyperbilirubinemia in Japanese Very Low Birthweight Infants Using Transcutaneous Bilirubinometry.

OBJECTIVES To assess the accuracy of transcutaneous bilirubin (TcB) measurements at 5 different body sites in Japanese very low birthweight (VLBW) infants and to determine a cut-off value of TcB to detect total serum/plasma bilirubin (TB) levels ≥10 mg/dL (171 μM). STUDY DESIGN In a prospective multicenter study, 85 Japanese VLBW infants were enrolled from 5 neonatal intensive care units duri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Clinical Chemistry

سال: 1983

ISSN: 0009-9147,1530-8561

DOI: 10.1093/clinchem/29.4.740