Diagnostic Cardiac Catheterization

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnostic Cardiac Catheterization in Infants and Children

Echocardiography has greatly influenced the catheterization laboratory patient profile. The remarkable diagnostic precision of this tool has essentially eliminated the need for preoperative diagnostic catheterization in many of the common congenital lesions, such as tetralogy of Fallot, total anomalous pulmonary venous return, and endocardial cushion defects , . On the other hand, echocardiogra...

متن کامل

Diagnostic Cardiac Catheterization in the Pediatric Population

Although the utility of diagnostic cardiac catheterization in the clinical setting has diminished over the last years, due to the emergence of noninvasive imaging modalities, such as echocardiography, magnetic resonance imaging and computed tomography, catheterization for diagnostic reasons still constitutes a valuable tool in certain parts in the workup of pediatric heart disease. As a result,...

متن کامل

Branch retinal artery occlusion after diagnostic cardiac catheterization.

A case of right branch retinal artery occlusion (BRAO) due to cholesterol-containing embolus following transfemoral cardiac catheterization is reported. It is extremely rare, however, cardiologists should be alert to any thromboembolic complications during and following cardiac catheterization and choose the suitable approach (either upper extremity or transfemoral).

متن کامل

Explanatory digital video disc with patients undergoing diagnostic cardiac catheterization.

The aim of this study was to evaluate knowledge of patients before outpatient diagnostic cardiac catheterization after viewing an explanatory Digital Video Disc, in a cardiology reference hospital. This cross-sectional study was carried out with patients undergoing their first cardiac catheterization and was performed from May to June 2009 in the hemodynamic sector. An instrument was used with ...

متن کامل

Contrast media-induced nephropathy following diagnostic and therapeutic cardiac catheterization.

C o r r e s p o n d ê n c i a : F r e d e r i c o T . U l t r a m a r i É estimado que o número de cateterismos cardíacos diagnósticos e terapêuticos nos países ocidentais seja, respectivamente, de 6.000 e 2.000 procedimentos por milhão de habitantes por ano, com uma demanda anual de 1.800 toneladas de iodo em todo o mundo para a fabricação dos meios de contraste (MC). Além disso, o número dest...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Circulation

سال: 2003

ISSN: 0009-7322,1524-4539

DOI: 10.1161/01.cir.0000070982.94049.a2