Diagnosing hydrosalpinx by three-dimensional ultrasonography in inversion mode
نویسندگان
چکیده
منابع مشابه
Three-dimensional Volumetric Ultrasonography of Enlarged Adrenal Gland in Dog
Objective: Detection and evaluation of adrenal glands are complex problems in conventional ultrasonography in dogs. Using three-dimensional (3D) ultrasonography (US) in adrenal gland volume evaluation can add new potential for further adrenal studies. Design: Descriptive study Animals: a total of 10 mix breed dogs Procedures: The dogs underwent two dimensional (2D) and 3D US of the adrenal g...
متن کاملThree-Dimensional Power Doppler Ultrasonography for Diagnosing Abnormally Invasive Placenta and Quantifying the Risk.
OBJECTIVE To test an objective ultrasound marker for diagnosing the presence and severity of abnormally invasive placenta. METHODS Women at risk of abnormally invasive placenta underwent a three-dimensional power Doppler ultrasound scan. The volumes were examined offline by a blinded observer. The largest area of confluent three-dimensional power Doppler signal (Area of Confluence [Acon], cm)...
متن کاملReference intervals of fetal cisterna magna volume by two-dimensional method using the multiplanar mode of three-dimensional ultrasonography*
OBJECTIVE To establish reference intervals for the fetal cisterna magna volume by means of two-dimensional (2D) method using the multiplanar mode of three-dimensional ultrasonography. MATERIALS AND METHODS Cross-sectional study with 224 healthy pregnant women between the 17th and 29th gestational weeks. The volume was automatically obtained by multiplying the three major axes in axial and sag...
متن کاملThree-Dimensional Color Doppler Ultrasonography Study of Normal Liver Vascular Pattern in Dog
Objective- To create three-dimensional model of the dog's liver vessels by using threedimensionalcolor Doppler ultrasonography which can be used for surgery planning,tumor detecting, transplantation, and other diagnostic or treatment project.Design- Descriptive studyAnimals- 6 mixed breed dog, 1.6-1.7 years old, 18-20 kg weightProcedures- The liver was found by two-dimensional scan initially th...
متن کاملUse of three-dimensional ultrasonography of the eye and measurement of optical long axis in dog
This study was conducted to determine the use of three-dimensional ultrasonography (3DU) in ocular imaging of the dog and measuring of its optical axis. 12 healthy mixed-breed dogs including 6 males and 6 females were studied. 3DU of the eyes were done using a 5–12 MHz linear trapezoid transducer. 3DU of the eyes were evaluated and the normal optical long axis through a line between the cornea ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Case Reports and Images in Obstetrics and Gynecology
سال: 2017
ISSN: 2582-0249
DOI: 10.5348/z08-2017-31-cs-11