Development of Patient Motion Tracking System during Radiation Therapy

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improving Radiation Therapy Through Motion Tracking

OF THE DISSERTATION Improving Radiation Therapy Through Motion Tracking by Hanlin Wan Doctor of Philosophy in Biomedical Engineering Washington University in St. Louis, 2016 Parag Parikh, Chair Radiation therapy is a widely-used cancer treatment method in which lethal doses of ionizing radiation are delivered to cancerous cells. Given the high dose requirements and the risk of associated compli...

متن کامل

Estimation of radiation dose of emergency exposure during the hospitalized 131I therapy patient

Background:  The aim of the study was to estimate the radiation dose during emergency exposure to patients treated with iodine-131 during the isolation period. Materials and Methods: The dose rate from a sample of 192 patients administrated by three different radioactivity of 131I (3.7, 5.55 and 7.4 GBq) was measured, at 1 meter after 1, 24 and 48 hours post dose administration, at three d...

متن کامل

Cherenkoscopy based patient positioning validation and movement tracking during post-lumpectomy whole breast radiation therapy.

To investigate Cherenkov imaging (Cherenkoscopy) based patient positioning and movement tracking during external beam radiation therapy (EBRT). In a phase 1 clinical trial, including 12 patients undergoing post-lumpectomy whole breast irradiation, Cherenkov emission was imaged with a time-gated ICCD camera synchronized to the LINAC pulse output, during different fractions of the treatment. Pati...

متن کامل

Implementation of an in‐house visual feedback system for motion management during radiation therapy

In this Technical Note, we describe an in-house video goggles feedback system assembled using several commercially available products. This goggle video feed-back system is currently being used at University of Louisville and Mayo Clinic for both CT simulation and linac treatment delivery. The setup details, including specific recommendations, are provided, along with an alternative option for ...

متن کامل

Surrogate-driven deformable motion model for organ motion tracking in particle radiation therapy.

The aim of this study is the development and experimental testing of a tumor tracking method for particle radiation therapy, providing the daily respiratory dynamics of the patient's thoraco-abdominal anatomy as a function of an external surface surrogate combined with an a priori motion model. The proposed tracking approach is based on a patient-specific breathing motion model, estimated from ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Indian Journal of Science and Technology

سال: 2015

ISSN: 0974-5645,0974-6846