Development of low radioactivity photomultiplier tubes for the XMASS-I detector
نویسندگان
چکیده
منابع مشابه
Photomultiplier Tubes
Light which enters a photomultiplier tube is detected and produces an output signal through the following processes. (1) Light passes through the input window. (2) Light excites the electrons in the photocathode so that photoelectrons are emitted into the vacuum (external photoelectric effect). (3) Photoelectrons are accelerated and focused by the focusing electrode onto the first dynode where ...
متن کاملPhotomultiplier Tubes
including basic and performance. For example, section 4.1 shows spectral response characteristics of typical photocathodes and also gives the definition of photocathode sensitivity and its measurement procedure. Section 4.2 explains dynode types, structures and typical characteristics. Section 4.3 describes various performance characteristics such as time response, operating stability, sensitiv...
متن کاملSearch for bosonic superweakly interacting massive dark matter particles with the XMASS-I detector.
Bosonic superweakly interacting massive particles (super-WIMPs) are a candidate for warm dark matter. With the absorption of such a boson by a xenon atom, these dark matter candidates would deposit an energy equivalent to their rest mass in the detector. This is the first direct detection experiment exploring the vector super-WIMPs in the mass range between 40 and 120 keV. With the use of 165.9...
متن کاملTesting of Cryogenic Photomultiplier Tubes for the MicroBooNE Experiment
The MicroBooNE detector, to be located on axis in the Booster Neutrino Beamline (BNB) at the Fermi National Accelerator Laboratory (Fermilab), consists of two main components: a large liquid argon time projection chamber (LArTPC), and a light collection system. Thirty 8inch diameter Hamamatsu R5912-02mod cryogenic photomultiplier tubes (PMTs) will detect the scintillation light generated in the...
متن کاملImprovement of 20 in. diameter photomultiplier tubes
The quality of the 20 in . photomultiplier tubes (Hamamatsu R1449) has been greatly improved over the required specifications for using them m the 50000 ton imaging water Cherenkov detector, Super-Kamiokande . In particular, the resolution of the timing response for single-photoelectron light has been reduced to 3 ns (1Q width), and a clear single-photoelectron peak can be seen in the pulse hei...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
سال: 2019
ISSN: 0168-9002
DOI: 10.1016/j.nima.2018.12.083