DEVELOPMENT OF AMPEROMETRIC BIOSENSOR BASED ON LACTATE OXIDASE FOR LACTATE DETERMINATION
نویسندگان
چکیده
منابع مشابه
Development of a screen-printed amperometric biosensor for the determination of L-lactate dehydrogenase level.
We attempted to develop a screen-printed biosensor for the amperometric determination of L-lactate dehydrogenase (LDH) level on the basis of NAD(+)/NADH-dependent dehydrogenase reaction. The printing ink for the working electrode consisted of L-lactate, NAD(+), composite polymer of hydroxyethyl cellulose with ethylene glycol, 3,4-dihydroxybenzaldehyde (3,4-DHB) as an electron transferring media...
متن کاملFabrication of L-lactate biosensor based on redox species mediated lactate oxidase using micro-device
Original article Lactate biosensor Lactate Oxidase TGA, K Fe(CN) Micro-device Cyclic voltammetry 3 6
متن کاملDetermination of serum lactate with alkylamine glass bound lactate oxidase.
Commercial lactate oxidase (Lactate:O2; oxidoreductase EC 1.1.3.2) from Pediococcus species was immobilized on to alkylamine glass beads (pore diameter 55 nm) through glutaraldehyde coupling with a conjugation yield of 3.2 mg/g support and 105% retention of initial activity. Immobilized enzyme showed maximum activity at pH 6.5, when incubated at 40 degrees C for 12 min and was used for determin...
متن کاملAscorbic Acid Determination by an Amperometric Ascorbate Oxidase-based Biosensor
The aim of this work is to develop a method for ascorbic acid determination in some fruit juices, by using an ascorbate oxidase-based amperometric enzyme electrode. The enzyme was immobilized on a nylon (Biodyne A) membrane by glutaraldehyde linking. The enzyme-membrane was consecutively attached to the polyethylene membrane of a Clark oxygen electrode, which functioned as transducer. The analy...
متن کاملDetermination of Blood Lactate Concentration: Reliability and Validity of a Lactate Oxidase-based Method
Int J Exerc Sci 2(2): 83-93, 2009. The measurement of blood lactate has long been used as marker of exercise intensity and training status. We compared a commercially available lactate oxidase spectrophotometric method (LO) to determine blood lactate levels to two previously validated methods, the lactate dehydrogenase spectrophotometric method (LDH), and the YSI 1500L Sport lactate analyzer (Y...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Sensor Electronics and Microsystem Technologies
سال: 2016
ISSN: 2415-3508,1815-7459