DEVELOPMENT AND VALIDATION OF STABILITY INDICATING METHOD RP-HPLC METHOD OF ACOTIAMIDE
نویسندگان
چکیده
منابع مشابه
Stability Indicating HPLC Method Development and Validation
High performance liquid chromatography (HPLC) is an integral analytical tool in assessing drug product stability. HPLC methods should be able to separate, detect, and quantify the various drug-related degradants that can form on storage or manufacturing, plus detect and quantify any drug-related impurities that may be introduced during synthesis. Forced degradation studies of new chemical entit...
متن کاملDevelopment and Validation of Stability Indicating Rp-hplc Method for Determination of Β-acetyldigoxin
Objective: The objective of the present study was to develop and validate a novel stability indicating reverse phase-high performance liquid chromatography (RP-HPLC) method for determination of β-acetyldigoxin, an active pharmaceutical ingredient (API). Methods: The chromatographic separation was carried out on Agilent Technologies 1200 series HPLC system equipped with photo diode array detecto...
متن کاملDevelopment and Validation of Stability indicating RP-HPLC Method for the estimation of Azithromycin Suspension
A RP-HPLC method was developed and validated for quantitative determination of azithromycin in pharmaceutical suspension dosage forms. The chromatography was carried out on a Phenomenex C 18 (150 x 4.6 mm i.d., 5μ) column with Acetonitrile: 0.5 % Formic acid as mobile phase (Isocratic A: B = 40: 60 % v/v), at 215 nm detector wave length with a flow rate of 1 ml/min. Clarithromycin was used as a...
متن کاملDevelopment and validation of a stability indicating RP-HPLC method for the determination of Rufinamide
A stability-indicating RP-HPLC method was developed and validated for the determination of Rufinamide in tablet dosage forms using C 18 column (250 mm×4.6 mm, 5 μm) with mobile phase consisting of water-acetonitrile (40:60, v/v) with a flow rate of 0.8 mL/min (UV detection 215 nm). Linearity was observed over the concentration range 1.0-200 μg/mL (R2=0.9997) with regression equation y=113190 x+...
متن کاملDevelopment and validation of stability-indicating RP-HPLC method for the determination of Nabumetone
A simple, precise, and accurate, isocratic, reversed RP-HPLC stability indicating method was developed and validated for determination of Nabumetone (Naphthyl acetic acid derivative). Isocratic RP-HPLC separation was achieved on Inert Sil ODS 3V (5μ, 25 cm× 4.6 mm, i.d.) column using mobile phase consisted of 0.47 g of tetrabutyl ammonium hydroxide sulphate (TBAH) dissolved in 1000 ml of a mixt...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Pharmacy and Pharmaceutical Sciences
سال: 2018
ISSN: 0975-1491
DOI: 10.22159/ijpps.2018v10i9.24925