Determination of Thiocyanate by Kinetic Spectrophotometric Flow Injection Analysis
نویسندگان
چکیده
منابع مشابه
Spectrophotometric determination of catecholamines with metaperiodate by flow-injection analysis
A flow-injection spectrophotometric method for the determination of adrenaline and isoprenaline, based on the reaction with metaperiodate, is described. The calibration graphs are linear up to 2X 10e4 M. Flow injection allows the measurement of 120 samples per hour. The method was successfully applied to the determination of both catecholamines in pharmaceuticals.
متن کاملUltra-trace Determination of Palladium(II) by Spectrophotometric Flow Injection Analysis
Nowadays, palladium compounds due to their especial characteristics used in different industries, mainly in electrical power sources and chemical productions as a catalyst. Therefore, Pd concentration is increasing in our around that can be contaminant our environment due its toxic effects. In this work, a simple, selective and rapid flow injection method of analysis (FIA) has been developed fo...
متن کاملKinetic-Spectrophotometric Determination of Thiocyanate Based on Its Inhibitory Effect on the Oxidation of Pyrogallol Red by Bromate
A kinetic spectrophotometric method for rapid measurement of thiocyanate in serum, urine and sewage water with no need for removed of interfering substances in described. The method is based on the inhibitory effect of thiocyanate on the oxidation of pyrogallol red by bromated and nitrite which is monitored at 467 nm. The variables affecting the rate of the reaction were investigated and th...
متن کاملFlow injection spectrophotometric determination of bromoxynil herbicide by diazotization method.
A flow injection spectrophotometric method is proposed for the determination of bromoxynil herbicide. Bromoxynil was hydrolyzed with HCl and the resulting product, 3,5-dibromo-4-hydroxyaniline, was diazotized with nitrite and coupled with aniline. The absorbance of the azo dye was measured at 500 nm. The conditions were optimized for diazotization using FIA. The range of linearity was found to ...
متن کاملFlow Injection Spectrophotometric Determination of Sulphide by Catalytic Reduction of Toluidine Blue
Sulphide was determined spectrophotometrically at 628 nm and pH 6.7 based on its catalytic reduction of toluidine blue in the presence of Se(IV) using a flow injection system. After optimization of the measuring conditions the calibration curve was found linear up to 25 mg/mL and the detection limit was 0.3 mg/mL (30 mL injections). The ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Chemistry
سال: 2013
ISSN: 2090-9063,2090-9071
DOI: 10.1155/2013/147364