Determination of phosphorus as heteropoly blue by hydrazine reduction.

نویسندگان

چکیده

منابع مشابه

Flow Injection Spectrophotometric Determination of Sulphide by Catalytic Reduction of Toluidine Blue

Sulphide was determined spectrophotometrically at 628 nm and pH 6.7 based on its catalytic reduction of toluidine blue in the presence of Se(IV) using a flow injection system. After optimization of the measuring conditions the calibration curve was found linear up to 25 mg/mL and the detection limit was 0.3 mg/mL (30 mL injections). The ...

متن کامل

flow injection spectrophotometric determination of sulphide by catalytic reduction of toluidine blue

sulphide was determined spectrophotometrically at 628 nm and ph 6.7 based on its catalytic reduction of toluidine blue in the presence of se(iv) using a flow injection system. after optimization of the measuring conditions the calibration curve was found linear up to 25 mg/ml and the detection limit was 0.3 mg/ml (30 ml injections). the relative standard deviation for the determination of 10 mg...

متن کامل

Developed New Procedure for Low Concentrations of Hydrazine Determination by Spectrophotometry: Hydrazine-Potassium Permanganate System

An indirect, sensitive and accurate method for the determination of trace amounts of hydrazine is described. In this proposed the spectrophotometric method is based on its reduction properties of hydrazine with a known concentration of potassium permanganate to reduce the colour. The absorbance of unreduced permanganate is measured the colour difference at different wavelengths 546 and 526 nm w...

متن کامل

Removal of methylene blue by mesoporous CuO/SiO2 as catalyst

Among a wide range of pollutants, organic pollutants have given rise to major environmental concerns. Various methods have been considered to mitigate the damage, including catalytic reduction to less hazardous compounds. Catalysts that benefit from high surface area and suitable surface sites for various steps of the catalytic reaction have shown outstanding results in performing such duties. ...

متن کامل

Simple Electrochemical Determination of Hydrazine in Water

Hydrazine in water samples is determined by constant current chronopotentiometry in porous carbon electrodes. Hydrazine in alkaline solutions is oxidised to nitrogen in the pores of the electrode by constant current. Two types of electrodes made of reticulated vitreous carbon (RVC) were used, one fabricated from crushed RVC particles, the other with the original RVC material of 100 ppi porosity...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: BUNSEKI KAGAKU

سال: 1962

ISSN: 0525-1931

DOI: 10.2116/bunsekikagaku.11.511