Determination of naproxen by using differential pulse voltammetry with poly (aniline-2-sulfonic acid) modified boron doped diamond electrode

نویسندگان

چکیده

In this study, an electrochemical sensor based on a boron doped diamond electrode (BDDE) was developed for the determination of naproxen (NAP) using poly(aniline-2-sulfonic acid)/boron electrode, p(A2SA/BDDE). Polymerization A2SA conducted in water/acetonitrile (1:1) mixture containing 0.1 M sodium perchlorate (NaClO4) bare BDDE and properties studied by cyclic voltammetry ferricyanide/KNO3 solution. The prepared p(A2SA/BDDE) used detection NAP. Effects parameters such as monomer type concentration, number cycles, scan rate were investigated differential pulse (DPV) phosphate buffer 0.75 mM effect electrolyte pH DPV responses to NAP also studied. oxidative current peak stem from concentration observed at 1.1 V potential. A linear calibration curve obtained range 0.05–1.00 concentration. Correlation coefficient (R2), limit, quantification limit calculated 0.9944, 0.0328 mM, 0.1093 respectively. conclusion, it may be claimed that modified constructed work can successfully naproxen-selective membrane due its ease preparation, high R2 value, good reproducibility.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Propylthiouracil in Pharmaceuticals by Differential Pulse Voltammetry Using a Cathodically Pretreated Boron-Doped Diamond Electrode

Um procedimento simples é descrito para a determinação de propiltiouracil (PTU) por voltametria de pulso diferencial (DPV) usando um eletrodo de diamante dopado com boro (BDD) pré-tratado catodicamente. Estudos por voltametria cíclica indicam que a oxidação do PTU é irreversível a um potencial de pico de 1,42 V (vs. Ag/AgCl (KCl 3,0 mol L-1)) em uma solução tampão de Britton-Robinson (BR) (pH 2...

متن کامل

Simultaneous Determination of Paracetamol and Ibuprofen in Pharmaceutical Samples by Differential Pulse Voltammetry Using a Boron-Doped Diamond Electrode

O presente trabalho apresenta uma metodologia simples, rápida e de baixo custo para determinação simultânea de paracetamol (PC) e ibuprofeno (IB) em formulações farmacêuticas por voltametria de pulso diferencial usando eletrodo de diamante dopado com boro (BDD). Os analitos apresentaram picos de oxidação definidos em 0,85 V para o PC e 1,72 V para o IB (vs. Ag/AgCl) sobre o eletrodo de trabalho...

متن کامل

DETERMINATION OF ULTRA-TRACE AMOUNTS OF COBALT BY ADSORPTIVE DIFFERENTIAL PULSE VOLTAMMETRY USING ACDA (2-AMINOCYCLOPENTENE- 1-DITHIOCARBOXYLIC ACID)

The present work describes a selective, rapid and sensitive method for the determination of cobalt using the adsorptive differential pulse voltammetry technique. The method is based on the accumulation of Co(II) complex with 2-aminocyclopentene-1-dithiocarboxylic acid on a hanging mercury drop electrode, followed by measurement of the current of the adsorbed complex. The effects of experimental...

متن کامل

Determination of vanillin in commercial food product by adsorptive stripping voltammetry using a boron-doped diamond electrode.

A method for the determination of food additive vanillin was developed by adsorptive stripping voltammetry. Its determination was carried out at the anodically pre-treated boron-doped diamond electrode in aqueous solutions. Using square-wave stripping mode, the compound yielded a well-defined voltammetric response in phosphate buffer, pH 2.5 at +1.14 V (vs. Ag/AgCl) (a pre-concentration step be...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Macedonian Journal of Chemistry and Chemical Engineering

سال: 2022

ISSN: ['1857-5552', '1857-5625']

DOI: https://doi.org/10.20450/mjcce.2022.2381