DETERMINATION OF LOCAL DIAGNOSTIC REFERENCE LEVEL (LDL) PEDIATRIC PATIENTS ON CT HEAD EXAMINATION BASED ON SIZE-SPECIFIC DOSE ESTIMATES (SSDE) VALUES
نویسندگان
چکیده
منابع مشابه
Size specific dose estimate (SSDE) for estimating patient dose from CT used in myocardial perfusion SPECT/CT
Objective(s): Size specific dose estimate (SSDE) is a new parameter that includes patient size factor in its calculation. Recent studies have produced mixed results on the utility of SSDE, especially when automatic exposure control (AEC) was used. The objective of the study was to find out if there is a relationship between patient size and each of the parameters, SSDE...
متن کاملDose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran
Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...
متن کاملDetermination of Diagnostic Reference Level in routine Computed radiography examination in north of Iran
Introduction: Digital radiography has a major role in nowadays healthcare system so radiation protection (justification and optimization) is important in this field. Many related organizations to protection suggested to establish national and regional diagnostic reference level for medical procedures. Reference levels are typically set at the 75th percentile of the dose distri...
متن کاملUse of Water Equivalent Diameter for Calculating Patient Size and Size-Specific Dose Estimates (SSDE) in CT: The Report of AAPM Task Group 220.
DISCLAIMER: This publication is based on sources and information believed to be reliable, but the AAPM, the authors, and the editors disclaim any warranty or liability based on or relating to the contents of this publication. The AAPM does not endorse any products, manufacturers , or suppliers. Nothing in this publication should be interpreted as implying such endorsement. 12 DISCLAIMER: This p...
متن کاملdose assessment in computed tomography examination and establishment of local diagnostic reference levels in mazandaran, iran
background : medical x-rays are the largest man-made source of public exposure to ionizing radiation. while the benefits of computed tomography (ct) are well known in accurate diagnosis, those benefits are not risk-free. ct is a device with higher patient dose in comparison with other conventional radiation procedures. objective: this study is aimed at evaluating radiation dose to patients from...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal Of Vocational Health Studies
سال: 2019
ISSN: 2580-717X,2580-7161