Designing hyperbolic secant excitation pulses to reduce signal dropout in gradient-echo echo-planar imaging

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Two-dimensional spatially-selective RF excitation pulses in echo-planar imaging.

Two-dimensional spatially-selective RF (2DRF) excitation pulses were developed for single-shot echo-planar imaging (EPI) with reduced field of view (FOV) in the phase-encoding direction. The decreased number of k-space lines significantly shortens the length of the EPI echo train. Thus, both gradient-echo and spin-echo 2DRF-EPI images of the human brain at 2.0 T exhibit markedly reduced suscept...

متن کامل

Echo-planar imaging.

Echo-planar imaging is a fast magnetic resonance (MR) imaging technique that allows acquisition of single images in as little as 20 msec and performance of multiple-image studies in as little as 20 seconds. Echo-planar imaging achieves its speed by obtaining all spatial-encoding information after a single radio-frequency (RF) excitation. Conventional imaging requires multiple-RF excitations, se...

متن کامل

Gradient preemphasis calibration in diffusion-weighted echo-planar imaging.

This article describes a method which enables fast and objective pulse-sequence-specific preemphasis calibration, using standard pulse sequences and system hardware. The method is based on a k-space measurement technique, and has been applied to single-shot, diffusion-weighted, spin-echo, echo-planar imaging (DW-SE-EPI), which is particularly sensitive to eddy-current-induced image distortions....

متن کامل

Perfusion-sensitive MR imaging of gliomas: comparison between gradient-echo and spin-echo echo-planar imaging techniques.

BACKGROUND AND PURPOSE The different sensitivities to vessel size of gradient-echo echo-planar imaging (GE-EPI) and spin-echo EPI (SE-EPI) might indicate the relative cerebral blood volumes (rCBVs) of different tumor sizes. The techniques of GE-EPI and SE-EPI were compared for detecting low- versus high-grade gliomas. METHODS Six patients with low-grade gliomas and 19 patients with high-grade...

متن کامل

Gradient echo imaging.

Magnetic resonance imaging (MRI) based on gradient echoes is used in a wide variety of imaging techniques and clinical applications. Gradient echo sequences form the basis for an essential group of imaging methods that find widespread use in clinical practice, particularly when fast imaging is important, as for example in cardiac MRI or contrast-enhanced MR angiography. However, the term "gradi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Magnetic Resonance in Medicine

سال: 2014

ISSN: 0740-3194

DOI: 10.1002/mrm.25444