In this paper we show how a fairly large proportion of those commutation failures that are due to single-phased short circuits to earth can be avoided. In a control circuit based on a digital signal processor (DSP) it is possible, with instantaneous results, to switch from a normal control strategy with equidistant firing pulses to a strategy that takes into consideration the potentially danger...

متن کامل

Mitigation of commutation faults in HVDC system

To transfer large amount of direct current power having high amplitude voltage over long distance, high voltage direct current (HVDC) transmission system is used. This system was introduced 60 year ago and now it is widely used all over the world. Some examples of HVDC systems are following; Voltage-SourcedConverter (VSC), current commutated converter (CCC) and line commutated converter (LCC) d...

متن کامل

HVDC Transmission with STATCOM

Most of the HVDC power converters with thyristor valves are assembled in a converter Bridge of Six pulse configuration. Converter transformers with one DC side winding as an ungrounded star connection and the other a delta configuration. Comparative studies of the two systems of HVDC CIGRE model without STATCOM and with STATCOM were performed. In these case, the consideration was the converter ...

متن کامل

To Investigate Environmental effects of HVDC versus HVAC Transmission Systems

Alternating current (AC) has few drawbacks which have increased the demand of Direct current (DC) Transmission. The normal HVAC range is between 220-800 kV .This high voltage has to pass different types of terrains including settled area, mountains and water. It is quite clear that human beings and environment will be effected from this huge voltage. The common effects of these huge voltages ar...

متن کامل

HVDC-based Fast Frequency Support for Low Inertia Power Systems

This paper analyses and compares different methodologies for supporting system frequency in low inertia power systems using HVDC interconnectors. Reduced system inertia, caused by the massive integration of converter-interfaced renewables and the displacement of conventional synchronous generation, can result in high values of rate of change of frequency (ROCOF), increasing the risk of frequenc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Transactions on Power Delivery

سال: 2000

ISSN: 0885-8977

DOI: 10.1109/61.871369