Decreased oxygen permeability of EVOH through molecular interactions
نویسندگان
چکیده
منابع مشابه
Increased permeability of oxygen atoms through graphene with ripples.
Graphene is an ideal membrane for selective separation because of its unique properties and single-layer structure. Considerable efforts have been made to alter the permeability of graphene. In this study, we investigate the pathways for an oxygen atom to pass through graphene sheets. We also identify the effect of the ripple's curvature in graphene sheets on the energy barrier of permeation th...
متن کاملOxygen-barrier films based on low-density polyethylene/ ethylene vinyl alcohol/ polyethylene-grafted maleic anhydride compatibilizer
In this research, high oxygen-barrier films were organized based on low-density polyethylene (LDPE)/ ethylene vinyl alcohol (EVOH)/ polyethylene-grafted maleic anhydride (LDPE-g-MA) compatibilizer. The effects of 10–30 wt. % EVOH and 0–10 wt. % LDPE-g-MA loadings on the properties of final films were evaluated. The morphology of specimens was observed by using scanning electron microscopy (SEM)...
متن کاملSwimbladder Permeability to Oxygen
The permeability of the swimbladder to gas was measured as the conductance to oxygen in seven species of fish. The low over-all conductance resides in the low diffusion constant, K, of the middle layer of the wall (submucosa) while the outer and inner layers (tunica externa and mucosa) have diffusion constants similar to other vertebrate tissues. The low diffusion constant is due to a low diffu...
متن کاملOxygen permeability of collagen shields.
The oxygen permeability (Dk) of ten 24-hr collagen shields was measured directly by polarographic methodology at approximately 2 hr of hydration. Edge and boundary effects were included in the calculations. Dk was found to be approximately 26 x 10(-11) cm ml O2/sec ml mmHg at 35 degrees C. Mean water content of the shields was 65.7% (SD = 1.0%) as measured by a hand refractometer. Therefore, th...
متن کاملBiophysics Oxygen permeability of phosphatidylcholine - cholesterol membranes ( pulse ESR / permeability coefficient / oxygen transport ) WITOLD
Oxygen transport in phosphatidylcholinecholesterol membranes has been studied by observing the collision of molecular oxygen with nitroxide radical spin labels placed at various distances from the membrane surface using long-pulse saturation recovery ESR techniques. The collision rate was estimated for tempocholine phosphatidic acid ester, 5-doxylstearic acid, and 16-doxylstearic acid from spin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Express Polymer Letters
سال: 2014
ISSN: 1788-618X
DOI: 10.3144/expresspolymlett.2014.78