Damage Identification of Unreinforced Masonry Panels Using Vibration-Based Techniques
نویسندگان
چکیده
منابع مشابه
Damage Accumulation in Unreinforced Masonry Due to Seismic Loading
Masonry has low cohesive strength and is susceptible to the brittle failure, when subjected to induced tensile stresses. It fails due to lateral tensile stresses even when masonry prisms are tested in uni-axial static compression and the stress-strain curve remains almost linear up to failure. Although masonry normally resists compressive forces, under lateral in-plane cyclic loads some parts o...
متن کاملFlexural Tension in Unreinforced Masonry
Unreinforced masonry is that in which the tensile strength of the masonry is taken into consideration in design. Allowable out-of-plane tensile stress values are a function of the mortar type, such as Portland cement/lime mortar vs. masonry cement mortar or type M or S mortar vs. type N mortar. The allowable tensile stress is also a function of the masonry construction, such as tension parallel...
متن کاملEffective stiffness of unreinforced brick masonry walls
Code design of Unreinforced Masonry (URM) buildings is based on elastic analysis, which requires as input parameter the effective stiffness of URM walls. Current approaches estimate the effective stiffness as fixed ratio of the gross sectional stiffness but comparisons with experimental results have shown that this does not yield satisfactory predictions. In this paper, a recently developed ana...
متن کاملTesting unreinforced masonry structures at reduced scale
When testing multi-story structures on a shaking table, most testing facilities require a reduced scale model. Producing scale test units at small scale is particularly challenging for unreinforced masonry structures. Previous work by other researchers showed that scaling of units and mortar joints is mandatory in order to obtain for the reduced scale masonry failure modes, which are similar to...
متن کاملTowards Displacement-Based Seismic Design of Modern Unreinforced Masonry Structures
Unreinforced masonry (URM) structures are known to be rather vulnerable to seismic loading. Modern URM buildings with reinforced concrete (RC) slabs might, however, have an acceptable seismic performance for regions of low to moderate seismicity. In particular in countries of moderate seismicity it is often difficult to demonstrate the seismic safety of modern URM buildings by means of force-ba...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Shock and Vibration
سال: 2017
ISSN: 1070-9622,1875-9203
DOI: 10.1155/2017/9161025