DAMAGE CONTROLLING PERFORMANCE OF UNBONDED POST-TENSIONED PRECAST CONCRETE WALLS
نویسندگان
چکیده
منابع مشابه
Precast, Pretensioned, Post-Tensioned Concrete for Bridge Decks
The problem of concrete bridge deck deterioration on many of our newer as well as older bridges is severe, somewhat perplexing as to cause, and difficult to solve. Furthermore, the cost to highway agencies for their repair, and the cost of delay to the highway user, can be extremely large. The use of precast, prestressed concrete for bridge decks is a con cept of construction or reconstruction...
متن کاملUnbonded Post Tensioned Concrete in Fire: A Review of Data from Furnace Tests and Real Fires
The fire-safe design of concrete structures which incorporate post-tensioned prestressing tendons has recently been the subject of debate within the structural engineering community, particularly when unbonded post-tensioned (UPT) prestressing tendons are used. Despite several studies aimed at furthering our understanding of the response of UPT concrete structures in fire, many aspects of their...
متن کاملUnbonded Post Tensioned Concrete Slabs in Fire – Part II – Modelling Tendon Response and the Consequences of Localized Heating
This is Part II of a two part paper dealing with the current state of knowledge of the fire-safe structural design and construction of unbonded post-tensioned (UPT) flat plate concrete structures. Part I provided detailed results of nineteen transient high temperature stress relaxation tests on restrained UPT tendons of realistic length and parabolic longitudinal profiles. Experimentation ident...
متن کاملDesign of Hybrid Precast Concrete Walls for Seismic Regions
This paper presents an ongoing research project on the behavior and design of “hybrid” precast concrete wall structures for use in seismic regions. Hybrid precast walls utilize a combination of mild (e.g., Grade 60) steel and high-strength unbonded post-tensioning (PT) steel for flexural resistance across horizontal joints. The mild steel reinforcement is designed to yield in tension and compre...
متن کاملSeismic Displacement Demands for Hybrid Precast Concrete Shear Walls
This paper presents an analytical investigation on the peak lateral displacement demands of “hybrid” precast concrete panelized shear wall structures under seismic loading. The hybrid wall structure investigated uses a combination of mild [i.e., Grade 400 (U.S. Grade 60)] steel bars and highstrength unbonded post-tensioning (PT) strands for lateral resistance across horizontal joints. The analy...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Structural and Construction Engineering (Transactions of AIJ)
سال: 2018
ISSN: 1340-4202,1881-8153
DOI: 10.3130/aijs.83.879