Current stress optimization control of isolated AC-DC matrix converter

نویسندگان

چکیده

Abstract The Isolated AC/DC matrix converter realizes bi-directional energy transmission through phase shift control. existing control schemes do not coordinate the modulation coefficient and ratio well, which will cause large current stress to converter, resulting in low efficiency. To solve this problem, paper analyses working mechanism of IAMC under dual It constructs a mathematical model calculate stress. An optimal method for isolated is proposed. suppressed by coordinating internal external ratio. Finally, simulation platform built verify proposed method.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multi-Stage DC-AC Converter Based on new DC-DC converter for energy conversion

This paper proposes a multi-stage power generation system suitable for renewable energy sources, which is composed of a DC-DC power converter and a three-phase inverter. The DC-DC power converter is a boost converter to convert the output voltage of the DC source into two voltage sources. The DC-DC converter has two switches operates like a continuous conduction mode. The input current of DC-DC...

متن کامل

Closed Loop Fuzzy Integrated Control of AC-DC Converter

Voltage fed single stage converters suffer from two main drawbacks: The efficiency is affected due to the reduced values of maximum DC link capacitor voltage and the power factor is not close to unity. To overcome these drawbacks, a boost type input current shaping converter, integrated with diode clamped topology is used. S ince this converter is a multilevel converter, it can be operated with...

متن کامل

Performance of Three Level Integrated AC-DC Converter with Hysteresis Current Control

In this paper, Performance of three-level integrated ac–dc converter with Hysteresis Current Control Technique is presented. The proposed converter combines with the operation of the boost power factor correction and the three-level dc–dc converter. By the implementation of Hysteresis Current controller, the switching sequence is under controlled condition and the output voltage of the proposed...

متن کامل

The Analysis of Ac-dc Boost Pfc Converter Based on Peak and Hysteresis Current Control Techniques

This paper presents two current control techniques of an ac-dc boost converter to obtain unity power factor (PF). Single phase high power factor rectification is the most frequently accomplished using a boost converter. This converter reshapes distorted input current waveform to approximate a sinusoidal current that is in phase with the input voltage. There are several current control technique...

متن کامل

Input Voltage and Current Sensorless Control of a Single Phase AC-DC Boost Converter

It is well known that measuring the input voltage and current, as the feedforward and feedback terms, are vital for the controller design in the problem of power factor compensation (PFC) of an AC-DC boost converter. Traditional adaptive scenarios corresponds to the simultaneous estimation of these variables are failed because the system dynamics is not in the classical adaptive form. In this p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of physics

سال: 2023

ISSN: ['0022-3700', '1747-3721', '0368-3508', '1747-3713']

DOI: https://doi.org/10.1088/1742-6596/2591/1/012037