Multichannel intraluminal impedance (MII) for the evaluation of esophageal diseases was created in 1991 trying to solve previous limitations of esophageal function test. MII-pH is able to determine the physical characteristics of the refluxate (liquid, gas, or mixed) and nonacidic GER. MII-manometry can determine the presence of bolus and its relation with peristalsis. This paper makes a critic...

متن کامل

Esophageal function testing using multichannel intraluminal impedance.

Multichannel intraluminal impedance (MII) is a new technique for evaluation of bolus transport. We evaluated esophageal function using bolus transport time (BTT) and contraction wave velocity (CWV) of liquid, semisolid, and solid boluses. Ten healthy subjects underwent MII swallow evaluation with various boluses of sterile water (pH 5), applesauce, three different sized marshmallows, and iced a...

متن کامل

Clinical Applications of Esophageal Multichannel Intraluminal Impedance Testing.

Multichannel intraluminal impedance is a relatively new technology that allows detection of bolus movement in the gastrointestinal tract without the use of radiation. In clinical applications it is combined with manometry, allowing a better evaluation of the functional characteristics (ie, bolus transit) of esophageal motility abnormalities. When combined with pH monitoring, it provides more co...

متن کامل

Examination of the Effects of Vardenafil on Esophageal Function Using Multichannel Intraluminal Impedance and Manometry

BACKGROUND/AIMS To evaluate the effects of the phosphodiesterase type 5 (PDE5) inhibitor vardenafil on esophageal function, including bolus transit, using multichannel intraluminal impedance and esophageal manometry (MII-EM). METHODS Sixteen healthy volunteers (15 men) underwent an MII-EM study including 10 liquid swallows and 10 viscous swallows in a seated position after fasting. Then, each...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: ISRN Gastroenterology

سال: 2012

ISSN: 2090-4401

DOI: 10.5402/2012/903240