Corrrection of exotropia by implantable collamer lens

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spontaneous Rotation of a Toric Implantable Collamer Lens

We present a case of toric implantable collamer lens (TICL) spontaneous rotation in a patient with myopic astigmatism. A 23-year-old female underwent TICL implantation. Preoperative uncorrected visual acuity (UCVA) was 20/800 and 20/1200, respectively, with -7.75 -4.25 × 0° and -8.25 -5.25 × 180°. The left eye achieved an UCVA of 20/30. After 3 months of successful implantation of TICL in the l...

متن کامل

More Than a Decade of Experience With Implantable Collamer Lens.

We read with great interest the article by Moya et al. in the August 2015 issue.1 The literature on longterm outcomes and complications of posterior chamber phakic intraocular lenses is scarce and the authors effectively describe their 12-year experience with implantable collamer lens (ICL) implantation. We reviewed 349 eyes of 216 patients, of which 155 (44.4%) were treated with spheric ICLs a...

متن کامل

Buffering zone of implantable Collamer lens sizing in V4c

BACKGROUND The purpose of this study was to identify factors related to the unexpected vault in V4c implantable collamer lens (ICL; STAAR Surgical) implantation. METHODS V4c ICLs were implanted in 43 eyes of 43 patients for the correction of myopia. The implanted V4c ICL sizes were determined individually with our previous V4 ICL sizing nomogram based on the sulcus-to-sulcus diameter (STS), a...

متن کامل

Implantable Collamer Lens - Morphological changes induced in the anterior segment

RESULTS: The mean vault values after the first month were 349.93 μm. They remained stable during the first 24 months of the follow-up period, with a slight tendency to decrease at 36 months which was not statistically significant. We observed a reduction in the anterior chamber angle, depth and volume of 14.23°, 167 μm and 60.44 mm3, respectively. This reduction remained stable during the follo...

متن کامل

Rotational stability of the V4b implantable collamer lens

RESULTS: No statistically significant differences were found in corneal astigmatism vectorial decomposition (J0 and J45) between the preoperative evaluation and each postoperative visit (p > 0.05). However, statistically significant differences in refractive astigmatism vectorial decomposition (J0 and J45) were found between preoperative and postoperative measurements (p < 0.05). Refractive ast...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Indian Journal of Ophthalmology

سال: 2013

ISSN: 0301-4738

DOI: 10.4103/0301-4738.119411