Corrosion of 316L in liquid tellurium at 551°C

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Liquid Metal Corrosion of 316L, Fe3AI, and FeCrSi in Molten Zn-AI Baths

Corrosion tests of 316L and two intermetallic compounds Fe3AI and FeCrSi in industrial Galvanizing (Zn-0.18Al), GALFAN (Zn-5AI), GALVALUME (Zn-55AI), and Aluminizing (AI-8Si) baths and lab-scale static baths were conducted. In on-line tests in industrial hot-dip baths, 316L steel shows better corrosion resistance than Fe3AI in Galvanizing, GALFAN, and GALVALUME baths. The corrosion resistance o...

متن کامل

Micro abrasion-corrosion of AISI 316L stainless steel

In this study, the synergistic effects of abrasion and corrosion on AISI 316L stainless steel have been investigated using a micro-abrasion test rig. A series of results from abrasioncorrosion tests conducted using the micro-abrasion rig are presented. AISI 316L stainless steel has been studied under both pure abrasion and abrasion-corrosion conditions simulated by either distilled water or 3.5...

متن کامل

Liquid Metal Corrosion of 316L Stainless Steel, 410 Stainless Steel, and 1015 Carbon Steel in a Molten Zinc Bath

Corrosion tests of 1015 low-carbon steel and two stainless steels (410 and 316L) were conducted in a pure zinc bath (99.98 wt pct Zn) in order to better understand the reaction mechanisms that occur during the degradation of submerged hardware at industrial general (batch) galvanizing operations. Through this testing, it was found that, in general, 316L stainless steel showed the best dissoluti...

متن کامل

Corrosion and Tissue Reaction to MP35N, L605 & 316L Guide Wires in Combination with a Conventional 316L Cannulated Stainless Steel Screw

INTRODUCTION: Cannulated screws, along with guide wires, are commonly used for a variety of orthopedic indications. Typically they are used for fractures in cancellous regions. Breakage or bending deformation of the guide wire is a clinical concern. Therefore it would be advantageous to use Co-Cr alloys such as MP35N and L605 in these applications as the occurrence of breakages and bendings wou...

متن کامل

Friction-corrosion of AISI 316L/bone cement and AISI 316L/PMMA contacts : ionic strength effect on tribological behaviour

Wear phenomena understanding of implants is a challenge: friction-corrosion of biomaterials, which constitute orthopaedic implants, is a significant issue concerning the aseptic loosening. This work aims at studying AISI 316L/bone cement friction which is a tribological problem related to hip joint cemented prostheses. This study focuses on the ionic strength effect on the tribological behaviou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Corrosion Science

سال: 2019

ISSN: 0010-938X

DOI: 10.1016/j.corsci.2019.02.001