Cooling scheme for W7-X divertor cryo-vacuum pumps
نویسندگان
چکیده
منابع مشابه
Database Structures and Interfaces for W7-X
The W7-X Experiment of the IPP, under construction in Greifswald Germany, is designed to operate in a quasi-steady-state scenario. The database structures and interfaces used for discharge description and execution have to reflect this continuous mode of operation. In close collaboration between the control group of W7-X and the data acquisition group a combined design of the data structures us...
متن کاملNASH Vacuum Pumps for Wastewater Treatment Plants
Many larger wastewater treatment plants use Anaerobic Digestion, a bacterial process that is carried out in the absence of oxygen. Compared to the conventional activated sludge process, Anaerobic Digestion is more energy efficient, reduces dewatered biosolids by 7-12 times (as compared to conventional processes) and produces useful methane gas (biogas). Gardner Denver Nash liquid ring pumps and...
متن کاملSizing Vacuum Pumps for Cleaning Milking Systems
Early pipeline milking systems were commonly flooded during cleaning. Flood cleaning is practical for systems with small diameter milklines, short pipelines and few milking units. Flood cleaning becomes impractical as milkline diameter and length and the number of milking units is increased. Excessive water volume is required and the flow velocities and corresponding mechanical cleaning action ...
متن کاملTomography by the maximum entropy method for the W7-AS and W7-X multichannel bolometer systems
Amaximum entropy approach has been applied to the tomographic inversion of the line integrated measurements of radiation power ux by a multichannel bolometer system. This method was applied to a H-mode discharge in the W7-AS stellarator, with increasing radiation from the plasma core after the transition being observed. Also a neutral beam injection discharge was investigated, and the time evol...
متن کاملOptimization of sample cooling temperature for redox cryo-imaging.
Cryo-imaging techniques have been widely used to measure the metabolic state of tissues by capturing reduced nicotinamide adenine dinucleotide (NADH) and flavin adenine dinucleotide (FAD) autofluorescence. However, NADH and FAD fluorescence is sensitive to changes in temperature, which may result in unreliable redox ratio calculations. Here, the relationship between the measured redox ratio and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Fusion Engineering and Design
سال: 2011
ISSN: 0920-3796
DOI: 10.1016/j.fusengdes.2011.03.063