Continuous monitoring of analyte concentrations.
We have investigated the application of a modified, heterogeneous, competitive enzyme immunoassay for the continuous measurement of small analytes in a medium stream. The analytical system contains two antibodies that are immobilized on spatially separated areas, one binding the analyte (Ab1) and the other binding the enzyme (Ab2). An analyte-enzyme conjugate serves as signal generator. The ana...
متن کاملContinuous Metabolic Monitoring Based on Multi-Analyte Biomarkers to Predict Exhaustion
This work introduces the concept of multi-analyte biomarkers for continuous metabolic monitoring. The importance of using more than one marker lies in the ability to obtain a holistic understanding of the metabolism. This is showcased for the detection and prediction of exhaustion during intense physical exercise. The findings presented here indicate that when glucose and lactate changes over t...
متن کاملcontinuous telemetric ecg monitoring
continuous telemetric ecg monitoring soltanzadeh l 1 , taheria 2 , reabiee m 3 * received: 29 may , 2013 accepted: 9 aug , 2013 abstract background & aims : diabetes mellitus is becoming a major public health problem. telecare can improve the quality of diabetes care by altering the caring environment and care delivery process. the electrocardiogram (ecg) is the recording of the...
متن کاملLine-Monitoring, Hyperspectral Fluorescence Setup for Simultaneous Multi-Analyte Biosensing
Conventional fluorescence scanners utilize multiple filters to distinguish different fluorescent labels, and problems arise because of this filter-based mechanism. In this work we propose a line-monitoring, hyperspectral fluorescence technique which is designed and optimized for applications in multi-channel microfluidic systems. In contrast to the filter-based mechanism, which only records flu...
متن کاملContinuous monitoring of oxygen concentrations in air-purged shake-flask fermentations.
Continuous monitoring of the oxygen concentrations in the gas and liquid phases in air-purged shake-flask fermentations was accomplished by means of steam-sterilizable oxygen probes.