Confinement and dynamics of laser-produced plasma expanding across a transverse magnetic field
نویسندگان
چکیده
منابع مشابه
Confinement and dynamics of laser-produced plasma expanding across a transverse magnetic field.
The dynamics and confinement of laser-created plumes expanding across a transverse magnetic field have been investigated. 1.06 microm, 8 ns pulses from a neodymium-doped yttrium aluminum garnet laser were used to create an aluminum plasma which was allowed to expand across a 0.64 T magnetic field. Fast photography, emission spectroscopy, and time of flight spectroscopy were used as diagnostic t...
متن کاملCharacterization of Expanding Laser Plasma Produced by Laser Ablation
This work is devoted to characterizing the plasma produced by nanosecond laser ablation. The expanding plasma was generated by the interaction of a home made XeCl excimer laser with a Cu target. The time-of-flight method was utilized as diagnostic tool of the plasma charged particles. By this method, in fact, we were able to measure the ion and electron currents, the charge-states and the energ...
متن کاملHeating and compression of a laser produced plasma in a pulsed magnetic field
Articles you may be interested in Spatially resolved behavior of laser-produced copper plasma along expansion direction in the presence of static uniform magnetic field Appl.
متن کاملExpansion dynamics of laser produced plasma
We consider the applicability of the isentropic, adiabatic gas dynamical model of plume expansion for laser ablation in vacuum. We show that the model can be applied to ionized plumes and estimate the upper electron temperature limit on the applicability of the isentropic approximation. The model predictions are compared with Langmuir ion probe measurements and deposition profiles obtained for ...
متن کاملCalibration of a Magnetic Field Probe as a Diagnostic for Laser-Produced Plasma
Small, high speed B-dot probes were constructed and calibrated as instruments to detect the spontaneous magnetic field of laser-produced plasma, following established techniques. A network analyzer and oscilloscopes were used to diagnose the source of interference observed both in the calibration of the probes and in the laser-plasma measurements. Methods of reducing the interference were formu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Physical Review E
سال: 2004
ISSN: 1539-3755,1550-2376
DOI: 10.1103/physreve.69.026413