Complementary dosimetry for a 6 MeV electron beam
نویسندگان
چکیده
منابع مشابه
Alanine-EPR dosimetry in 10 MeV electron beam to optimize process parameters for food irradiation
Absorbed dose in food product is determined and controlled by several parameters of the LINAC irradiation facility as well as those of the product. Standardization of the parameters characterizing the facility parameters, process load and the irradiation conditions collectively termed as ‘process parameters’ are important for successful dose delivery to the food products. In the present study, ...
متن کاملOptimization of Dual Scattering Foil for 6 to 20 MeV Electron Beam Radiotherapy
From last 50 years, electron beam therapy has an important radiation therapy modality. The electron beam from the LINAC is of size ∼ 2 mm, whereas the size required for actual treatment is usually larger than 2 × 2 cm up to 25 × 25 cm at the isocenter. In the present work, it is proposed to use dual scattering foil system for production of clinical electron beam. The foils for 6 to 20 MeV elect...
متن کاملDesign of dual scattering foil for 6 to 20 MeV electron beam radiotherapy
The electron beam from the linear accelerator is of size ~ 2 mm, whereas the size of the electron beam profile required for actual treatment is usually larger than 2 2 cm up to 30 30 cm at the iso-center. Therefore, scattering foils were optimized and simulated using FLUKA code. The primar scattering foil as kept niform thickness y w u , whereas the secondary foil was of Gaussian shape with var...
متن کاملElectron Beam Dosimetry in Heterogeneous Phantoms Using a MAGIC Normoxic Polymer Gel
Introduction: Nowadays radiosensitive polymer gels are used as a reliable dosimetry tool for verification of 3D dose distributions. Special characteristics of these dosimeters have made them useful for verification of complex dose distributions in clinical situations. The aim of this work was to evaluate the capability of a normoxic polymer gel to determine electron dose distributions in differ...
متن کاملTwo New Parallel-plate Ionization Chambers for Electron Beam Dosimetry
-Two parallel-plate ionization chambers were projected, constructed and evauated for use in high energy electron beams. They were constructed using the two plastic materials recommended for clinical dosimetry protocols, i.e. acrylic and polystyrene. Both chambers have cylindrical shape with entrance windows in aluminized Mylar and they are open to the air. The acrylic chamber has a 2 mm air gap...