Comparison of Trabecular Bone Mineral Density Measurement Using Hounsfield Unit and Trabecular Microstructure in Orthodontic Patients Using Cone-Beam Computed Tomography

نویسندگان

چکیده

The aim of this study was to measure the bone mineral density specific regions maxilla, mandible, and first cervical vertebra using Hounsfield unit trabecular microstructure pattern analysis compare two methods. In study, cone-beam computed tomography (CBCT) images were obtained from 58 patients. Trabecular thickness, number, separation, volume fraction measured in 484 for parameters grayscale value. There no difference between right left side every site males females. thickness number high order anterior base mandibular body, vertebra, condyle. Bone condyle, (p < 0.05). positively correlated unit, separation negatively 0.005). This suggests that it is possible various sites analysis.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

comparison of tissue density in hounsfield units in computed tomography and cone beam computed tomography

objectives: bone quality and quantity assessment is one of the most important steps in implant treatment planning. different methods such as computed tomography (ct) and recently suggested cone beam computed tomography (cbct) with lower radiation dose and less time and cost are used for bone density assessment. this in vitro study aimed to compare the tissue density values in hounsfield units (...

متن کامل

Comparison of Tissue Density in Hounsfield Units in Computed Tomography and Cone Beam Computed Tomography

OBJECTIVES Bone quality and quantity assessment is one of the most important steps in implant treatment planning. Different methods such as computed tomography (CT) and recently suggested cone beam computed tomography (CBCT) with lower radiation dose and less time and cost are used for bone density assessment. This in vitro study aimed to compare the tissue density values in Hounsfield units (H...

متن کامل

The relationship between dental implant stability and trabecular bone structure using cone-beam computed tomography.

PURPOSE The objective of this study was to investigate the relationships between primary implant stability as measured by impact response frequency and the structural parameters of trabecular bone using cone-beam computed tomography(CBCT), excluding the effect of cortical bone thickness. METHODS We measured the impact response of a dental implant placed into swine bone specimens composed of o...

متن کامل

Cone-beam computed tomography images of phantoms with simulating trabecular bone structure fabricated using micro-stereolithography.

OBJECTIVE Phantoms with simulating mandibular trabecular bone structure fabricated using micro-stereolithography were applied for a quantitative evaluation of cone-beam computed tomography (CT) images. MATERIALS AND METHODS Phantoms with a three-dimensional lattice, in which a square pillar was set at 0.10, 0.20, 0.30 and 0.40 mm at the edge, spaced at 0.60 mm, were made of an acrylic resin u...

متن کامل

Trabecular bone structural parameters evaluated using dental cone-beam computed tomography: cellular synthetic bones

OBJECTIVE This study compared the adequacy of dental cone beam computed tomography (CBCT) and micro computed tomography (micro-CT) in evaluating the structural parameters of trabecular bones. METHODS The cellular synthetic bones in 4 density groups (Groups 1-4: 0.12, 0.16, 0.20, and 0.32 g/cm3) were used in this study. Each group comprised 8 experimental specimens that were approximately 1 cm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Applied sciences

سال: 2021

ISSN: ['2076-3417']

DOI: https://doi.org/10.3390/app11031028