Comparison of Semi-Automated and Manual Measurements of Carotid Intima-Media Thickening
نویسندگان
چکیده
منابع مشابه
Comparison of Semi-Automated and Manual Measurements of Carotid Intima-Media Thickening
Carotid intima-media thickening (CIMT) is a marker of both arteriosclerotic and atherosclerotic risks. Technological advances have semiautomated CIMT image acquisition and quantification. Studies comparing manual and automated methods have yielded conflicting results possibly due to plaque inclusion in measurements. Low atherosclerotic risk subjects (n = 126) were recruited to minimise the effe...
متن کاملComparison between automated and manual measurements of carotid intima-media thickness in clinical practice
BACKGROUND AND AIM The measurement of carotid intima-media thickness (cIMT) has been used as a marker of arterial wall disease. Manual measurements have been performed in most epidemiological studies, but, due to the introduction of new technologies, automated software has been increasingly used. This study aimed to compare manual versus automated cIMT measurements in common carotid (CC), bifur...
متن کاملCarotid intima-media thickness and hemodynamic parameters: reproducibility of manual measurements with Doppler ultrasound.
AIMS To evaluate the carotid ultrasound intra- and interobserver agreements in a common clinical scenario when making manual measurements of the intima-media thickness (IMT) and peak systolic (PSV) and end diastolic (EDV) velocities in the common (CCA) and the internal carotid (ICA) arteries. MATERIAL AND METHODS Three different experienced operators performed two time-point carotid ultrasoun...
متن کاملComparison of the Intima-media Thickness of Carotid Artery in Children with Diabetes Type One and Control Group Using Ultrasound
Background & Aims: Diabetes is a very important factor for stroke due to blocked blood vessels. It can involve systemic and cerebrovascular arteries at the same time via microangiopathy and macroangiopathy. This project aimed to compare the intima-media thickness of carotid artery in children with diabetes type and the control group. Methods: In this case-control study, 50 children with the age...
متن کاملVariability of automated carotid intima-media thickness measurements by novice operators.
Carotid intima-media thickness (C-IMT) measurements provide a non-invasive assessment of subclinical atherosclerosis. The aim of the study was to assess the inter- and intra-observer variability of automated C-IMT measurements undertaken by two novice operators using the Panasonic CardioHealth Station. Participants were free from cardio-metabolic disease, and each underwent serial bilateral C-I...