Comparison of Post-Procedural and 30-day Post-Implantation Transcatheter Aortic Valve Replacement Gradients with and without pre-implantation Balloon Valvuloplasty: A Real-World Analysis of Early Results using a Novel Balloon Expandable Transcatheter Aortic Valve

نویسندگان

چکیده

Objectives: This study describes a real-world experience of implanting novel balloon expandable transcatheter aortic valve replacement (TAVR) compared to devices commonly used in clinical practice. As secondary objective, the effect angioplasty (BAV) before TAVR on transvalvular gradient 1 and 30 days after implantation was evaluated. Background: For most commercial valves, 30-day average mean gradients have been reported. Our with Lotus Valve System had indicated higher immediate post-implant than those literature. We sought evaluate both these comparing them other valves. Methods: analyzed discharge echocardiograms valves from 7/5/2019 8/27/2020. In response higher-than-expected gradients, patients 11/4/19 8/27/20 underwent BAV implantation, whereas 7/5/19 10/18/19 did not (no-BAV). samples each random sampling implanted by same interventionalist. Results: At discharge, 27 received The 16.7 mmHg (SD = 5.5 mmHg) for no-BAV 14.7 3.7 (P 0.177) cohorts. No-BAV were significantly < 0.001) Sapien (M 12 mmHg, SD 4.3) CoreValve 9.18 3.96). assessment, groups similar literature 11 3.5; M 4.1 0.287)) Conclusions: demonstrated post-implantation attenuated BAV. These elevated significant at follow-up.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcatheter Aortic Valve Replacement: A Review Article

Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...

متن کامل

Use of balloon aortic valvuloplasty to size the aortic annulus before implantation of a balloon-expandable transcatheter heart valve.

OBJECTIVES Our aim was to describe the use of balloon aortic valvuloplasty (BAV) to select proper transcatheter heart valve (THV) size. BACKGROUND Transesophageal echocardiogram (TEE) measurement alone of the aortic annulus may not be adequate to select a THV size. BAV can more accurately size the aortic annulus. We report our experience using this strategy in patients undergoing THV implanta...

متن کامل

Transapical transcatheter aortic valve implantation without prior balloon aortic valvuloplasty: feasible and safe.

OBJECTIVES Currently, preimplant balloon aortic valvuloplasty (BAV) is considered a prerequisite for successful subsequent transapical transcatheter aortic valve implantation (TA-TAVI) using balloon-expandable devices. However, cerebral embolization has been shown to originate at least in part from BAV procedures. Omitting BAV may therefore reduce neurological events after TAVI and facilitate t...

متن کامل

Preparatory balloon aortic valvuloplasty during transcatheter aortic valve implantation for improved valve sizing.

OBJECTIVES This study sought to evaluate whether supra-aortic angiography during preparatory balloon aortic valvuloplasty (BAV) improves valve sizing. BACKGROUND Current recommendations for valve size selection are based on annular measurements by transesophageal echocardiography and computed tomography, but paravalvular aortic regurgitation (PAR) is a frequent problem. METHODS Data of 270 ...

متن کامل

Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement.

BACKGROUND Aortic root rupture is a major concern with balloon-expandable transcatheter aortic valve replacement (TAVR). We sought to identify predictors of aortic root rupture during balloon-expandable TAVR by using multidetector computed tomography. METHODS AND RESULTS Thirty-one consecutive patients who experienced left ventricular outflow tract (LVOT)/annular/aortic contained/noncontained...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Cardiovascular innovations and applications

سال: 2022

ISSN: ['2009-8782', '2009-8618']