Comparison of irradiated foil measurements with activation calculations and HPGe simulations
نویسندگان
چکیده
منابع مشابه
a comparison of teachers and supervisors, with respect to teacher efficacy and reflection
supervisors play an undeniable role in training teachers, before starting their professional experience by preparing them, at the initial years of their teaching by checking their work within the proper framework, and later on during their teaching by assessing their progress. but surprisingly, exploring their attributes, professional demands, and qualifications has remained a neglected theme i...
15 صفحه اولthe past hospitalization and its association with suicide attempts and ideation in patients with mdd and comparison with bmd (depressed type) group
چکیده ندارد.
Precise efficiency calibration of an HPGe detector: source measurements and Monte Carlo calculations with sub-percent precision.
With the goal of measuring precise gamma-ray intensities for short-lived (< 5 s) accelerator-produced activities, we have calibrated the efficiency of an HPGe detector between 53 and 1836keV to sub-percent precision with a combination of source measurements and Monte Carlo calculations. Using known or independently measured detector dimensions, we have achieved both relative and absolute agreem...
متن کاملRadiation measurements in secondary elctron beam and comparison with calculations.
A high energy particle beamline is described which is capable of transporting a high intensity electron beam to potentially occupied areas. Ionization chamber measurements of electron beam intensity are described together with the ion chamber calibration and necessary corrections. The results of the measurements are compared with a Monte Carlo calculation of the electron intensity. (Submitted t...
متن کاملActivation of Radioadaptive Response via Injected Serum of Irradiated Rats with Low Doses of Ionizing Radiation
Introduction: One of the protective concepts in the interpretation of radiation damage in radiobiology is the radioadaptive response. The objective of this present report is to evaluate the induction of radioadaptive response in male rats by injection of pre-irradiated serum with low doses X-radiation intraperitoneally. Materials and Methods: 80 male adul...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Radioanalytical and Nuclear Chemistry
سال: 2018
ISSN: 0236-5731,1588-2780
DOI: 10.1007/s10967-018-5820-6