Comparison of Individual Air-Side Row-By-Row Heat Transfer Coefficient Correlations on Four-Row Finned-Tube Heat Exchangers
نویسندگان
چکیده
Each row of the heat exchanger (HEX) has different hydraulic-thermal characteristics. When air velocity upstream HEX is lower than approximately 3 m/s, exchanged flow rates at first rows tubes are higher average value for entire HEX. The article presents determination individual correlations air-side Nusselt numbers on each a 4-row finned with continuous flat fins and round in staggered tube layout. method was built based computational fluid dynamics modeling. Mass temperatures were simulated over dozen airflow velocities, from 2.5 m/s to 10 m/s. obtained number will enable selecting optimum given output investment costs can be reduced by decreasing number. Moreover, operating also lowered, as pressure losses lower, which turn enables reduction fan power.
منابع مشابه
Friction Loss and Heat Transfer Coefficient in Finned Tube Heat Exchangers for Reheating Massecuites
Equations developed for packed columns may be used to predict the overall heat transfer coefficient and friction loss in massecuite reheaters. The results seem to indicate that exchangers with the tubes staggered give higher heat transfer rates than those with the tubes in line.
متن کاملApplication of ZnO/TiO2 Nanocomposite for the Improvement of Heat Transfer Coefficient in Tube Heat Exchangers
The potential of nanofluids for the improvement of heat transfer coefficient in various heat exchangeequipment has been considered and studied as a major application during recent decades. In this research,heat transfer coefficient of ZnO, TiO2 and ZnO/TiO2 nanofluids in a shell and tube heat exchanger has beenstudied experimentally. ZnO nanoparticle was synthesized through pre...
متن کاملRefrigerant Circuit Optimization of Dual-mode Single-Row Microchannel Heat Exchangers used for R410A Heat Pumps
Microchannel heat exchangers (MCHX) are being increasingly applied in heat pumps because of their compactness, significant charge reduction, lower refrigerant pressure drop and lower air-side fan power consumption compared to traditional round tube-plate fin (RTPF) heat exchangers. Using a microchannel condenser as well as evaporator in a heat pump system also offers significant potential for c...
متن کاملFull Analysis of Low Finned Tube Heat Exchangers
In this paper, first the governing parameters characterizing low-finned tubes are reviewed. Second, the more important of the available performance correlations are compared with the available experimental data. The most reliable one can be employed to develop a pressure drop relationship, which has already been used in an algorithm for exchanger sizing. Also a means for the identification of a...
متن کاملThe effect of Geometrical parameters on heat transfer coefficient in helical double tube exchangers
Helical coil heat exchangers are widely used in industrial applications ranging fromcryogenic processes, air-conditioning, and nuclear reactors to waste heat recovery due totheir compact size and high heat transfer coefficient. In this kind of heat exchangers, flowand heat transfer are complicated. This paper reports a numerical investigation of theinfluence of different parameters such as coil...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Heat Transfer Engineering
سال: 2022
ISSN: ['0145-7632', '1521-0537']
DOI: https://doi.org/10.1080/01457632.2022.2113456