Comparison between the influence of implant diameter and implant length on the primary stability
نویسندگان
چکیده
منابع مشابه
the effect of implant length and diameter on the primary stability in different bone types.
the focus of this paper is to evaluate the influence of mechanical characteristics of the implant on primary stability in different bone types, based on resonance frequency analysis (rfa).a number of 60 nobel biocare replace select tiunit tapered implants of two different lengths (10 mm and 13 mm) and three different widths as 3.4 mm (narrow platform (np)), 4.3 mm (regular platform (rp)) and 5 ...
متن کاملThe Effect of Implant Length and Diameter on the Primary Stability in Different Bone Types
OBJECTIVE The focus of this paper is to evaluate the influence of mechanical characteristics of the implant on primary stability in different bone types, based on resonance frequency analysis (RFA). MATERIALS AND METHODS A number of 60 Nobel Biocare Replace Select TiUnit Tapered implants of two different lengths (10 mm and 13 mm) and three different widths as 3.4 mm (narrow platform (NP)), 4....
متن کاملon translation of phatic communion and socio-cultural relationships between the characters of the novels
phatic communion is a cultural concept which differs across cultures. according to hofstede (2001), the u.s. tends to have individualistic culture; however, asian countries tend to have collectivistic cultures. these cultures view phatic communion differently. in individualistic cultures like u.s., phatic communion reflects speakers’ socio-cultural relationships in conversations. to see whether...
15 صفحه اولon the relationship between the knowledge of collocations and writing proficiency
بررسی رابطه دانش همنشینی لغات و مهارت نوشتاری در زبان انگلیسی چکیده این پژوهش درصدد آن است تا سه مسئله زیر را مورد بررسی قرار دهد: الف) وجود یا عدم وجود رابطه بین دانش زبان آموزان در حوزه همنشینی لغات با یکدیگر و دانش آنها در مهارت نوشتاری زبان انگلیسی؛ ب) یافتن پاسخی به این سوال که آیا تمامی انواع همنشینی های لغوی زبان انگلیسی به یک میزان برای زبان آموزان دشوارند یا خیر؛ پ) مقایسه زبان آمو...
15 صفحه اولEffect of mini-implant length and diameter on primary stability under loading with two force levels.
Mini-implants are widely utilized as anchorage units in orthodontic treatment. Nevertheless, there are factors that interfere with their clinical performance. The aim of this study was to examine the impact of length and diameter on the primary stability of two different types of orthodontic mini-implants loaded with two force levels. A total of 90 self-drilling mini-implants were inserted in b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Scripta Scientifica Medicinae Dentalis
سال: 2018
ISSN: 2367-7244,2367-7236
DOI: 10.14748/ssmd.v4i2.5635