Comparison between Immunoturbidimetry, Size-Exclusion Chromatography, and LC-MS to Quantify Urinary Albumin

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison between immunoturbidimetry, size-exclusion chromatography, and LC-MS to quantify urinary albumin.

BACKGROUND The accurate and precise measurement of urinary albumin is critical, since even minor increases are diagnostically sensitive indicators of renal disease, cardiovascular events, and risk for death. To gain insights into potential measurement biases, we systematically compared urine albumin measurements performed by LC-MS, a clinically available immunoturbidimetric assay, and size-excl...

متن کامل

Quantification of urinary albumin by using protein cleavage and LC-MS/MS.

BACKGROUND Urinary albumin excretion is a sensitive diagnostic and prognostic marker for renal disease. Therefore, measurement of urinary albumin must be accurate and precise. We have developed a method to quantify intact urinary albumin with a low limit of quantification (LOQ). METHODS We constructed an external calibration curve using purified human serum albumin (HSA) added to a charcoal-s...

متن کامل

A Double-Barrel Liquid Chromatography- Tandem Mass Spectrometry (LC-MS/MS) System to Quantify 96 Interactomes per Day*□S

The field of proteomics has evolved hand-in-hand with technological advances in LC-MS/MS systems, now enabling the analysis of very deep proteomes in a reasonable time. However, most applications do not deal with full cell or tissue proteomes but rather with restricted subproteomes relevant for the research context at hand or resulting from extensive fractionation. At the same time, investigati...

متن کامل

A Double-Barrel Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) System to Quantify 96 Interactomes per Day*

The field of proteomics has evolved hand-in-hand with technological advances in LC-MS/MS systems, now enabling the analysis of very deep proteomes in a reasonable time. However, most applications do not deal with full cell or tissue proteomes but rather with restricted subproteomes relevant for the research context at hand or resulting from extensive fractionation. At the same time, investigati...

متن کامل

Determination of Ceruloplasmin in Human Serum by Immunoaffinity Chromatography and Size-Exclusion Chromatography-ICP-MS

A new method is described for the analysis of copper (Cu) containing ceruloplasmin (Cp) in human serum. The method uses immunoaffinity plus size-exclusion chromatography (SEC) to separate Cp from other proteins and from inorganic ions, with inductively coupled plasma mass spectrometry (ICP-MS) detection of 63Cu and 65Cu to identify the protein. A reference serum certified for Cp was used to est...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Clinical Chemistry

سال: 2008

ISSN: 0009-9147,1530-8561

DOI: 10.1373/clinchem.2008.107508