Objective: To study the effects of distal uniplanar locking and bi planar on union times in uncomplicated fractures shaft tibia managed with an intramedullary interlocking nail.
 Study Design: Comparative prospective study.
 Place Duration Study: Department Orthopedics Trauma Combined Military Hospital Rawalpindi from Jan to Nov 2020.
 Methodology: Fifty-three patients having nail were studied. Twenty-nine using two screws distally (uniplanar) coronal plane (group-1). Twenty-four three comprising one sagittal screw (group-2). Patients followed every 4 weeks, bone time was assessed. Isolated closed treated reduction included.
 Results: (group-2) had significantly reduced weeks (11.25 ± 1.42) compared (group-1) (15.79 1.80) (p<.001).
 Conclusion: Union for is when biplanar locking; it can be attributed increased stability construct.
منابع مشابه
The Role of Biplanar Distal Locking in Intramedullary Nailing of Tibial Shaft Fractures
Background: To compare the union times of the uncomplicated tibial shaft fractures, which were distally locked by twocoronal and one sagittal screws and by only two coronal screws.Methods: 45 patients with tibial shaft treated with intramedullary nailing included in this study. 23 of 45 fractureswere treated with uniplanar two distal interlocking (Group 1) and 22 fractures were treated with bip...
متن کاملDistal Locking Screws for Intramedullary Nailing of Tibial Fractures.
Recently introduced tibial intramedullary nails allow a number of distal screws to be used to reduce the incidence of malalignment and loss of fixation of distal metaphyseal fractures. However, the number of screws and the type of screw configuration to be used remains obscure. This biomechanical study was performed to address this question. Thirty-six Expert tibial nails (Synthes, Oberdorf, Sw...
متن کاملBiomechanical comparison of distal locking screws for distal tibia fracture intramedullary nailing
Background: Newer generation intramedullary (IM) tibial nails provide several distal interlocking screw options. The objectives were to determine: 1) if the new oblique interlocking option provides superior stability, 2) which screw orientation/ configuration is the most biomechanically stable, and 3) if three distal interlocking screws provide better stability. Methods: A preliminary experimen...
متن کاملUnreamed intramedullary nailing with oblique proximal and biplanar distal interlocking screws for proximal third tibial fractures.
PURPOSE To assess the outcome of unreamed intramedullary nailing through the lateralised entry point using oblique proximal and biplanar distal interlocking screws. METHODS 15 men and 3 women aged 25 to 58 (mean, 37) years underwent unreamed intramedullary nailing with oblique proximal and biplanar distal interlocking screws for proximal third metaphyseal tibial fractures. The entry point was...
متن کاملDistal third tibia fractures treated with interlocking intramedullary nail
The management of extraarticular fracture of the distal tibia remains controversial. Surgeons are not very keen on using intramedullary interlocking nail for these fractures because of diffi cult nail fi xation, wider medullary canal in the distal tibia and late angulation .The advent of newer nails with locking holes in the distal parts has made nailing possible even in cases of distal tibia f...