Comparative performance investigation of a dual evaporator cycle using an ejector with the conventional cycle using a pressure reducing valve
نویسندگان
چکیده
Abstract The performance of a dual evaporator cycle using ejector is compared with conventional employing pressure reducing valve. In both the systems, high temperature considered as flooded evaporator, thus separator employed after evaporator. However, low kind dry comparison i.e., and assisted, done for same cooling capacities dryness fraction at exit R134a, R152a, R1234yf refrigerants. effects varying states refrigerant temperatures evaporators condenser are analyzed Engineering Equation Solver. It found that compressor work reduced in cycles rise temperature; however, little variation observed total effect. effect increased increase but it decreased
منابع مشابه
Exergy, exergoeconomic and exergoenvironmental studies and optimization of a novel triple-evaporator refrigeration cycle with dual-nozzle ejector using low GWP refrigerants
In this work, a novel dual-nozzle ejector enhanced triple-evaporator refrigeration cycle (DETRC) without separator is proposed to improve the performance of the conventional ejector one (CETRC). The performance of DETRC is analyzed and compared with CETRC in term of energy coefficient of performance (COPen). Under given operating conditions, the COPen improvement of the no...
متن کاملan investigation of the types of text reduction in subtitling: a case study of the persian film gilaneh with english subtitles
چکیده ندارد.
15 صفحه اولPerformance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant
Since long time, it has been noticed that refrigerators are the devices which work almost 365 days round the clock; hence objective of energy efficiency improvement attracts much. There are several ways of improving the performance of a vapor compression refrigeration cycle. Use of an ejector as expansion device is one of the alternative way. The advent of new component ‘Ejector’ into refrigera...
متن کاملExperimental Study on the Performance of Dual-Evaporator Refrigeration System with an Ejector
Experimental investigation on the performance of dual-evaporator refrigeration system with an ejector has been carried out In this study, HFC-134a is chosen as a working fluid. Test setup is composed of compressor, condenser, expansion valves, two evaporators, and ejector which is installed between two evaporators. The condenser and two evaporators are made as concentric counter-flow type heat ...
متن کاملan investigation into translation of cultural concepts by beginner and advance student using think – aloud protocols
this research aims at answering the questions about translation problems and strategies applied by translators when translating cultural concepts. in order to address this issue, qualitative and quantitative study were conducted on two groups of subjects at imam reza international university of mashhad. these two groups were assigned as beginner and advanced translation students (10 students). ...
ذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Air-Conditioning and Refrigeration
سال: 2023
ISSN: ['2010-1333']
DOI: https://doi.org/10.1007/s44189-023-00036-6