Comparative Analysis of XLPE and Thermoplastic Insulation-Based HVDC Power Cables
نویسندگان
چکیده
The application of cross-linked polyethylene (XLPE) cables to voltage sourced converter (VSC)-based high direct current (HVDC) systems has already been technically verified and become common, thermoplastic (TP) is attracting attention as an insulation material for next-generation due the recent development material-related technologies. However, studies related TP are mainly focused on improving properties, cable insufficient. In this paper, XLPE were designed VSC-based HVDC systems, major characteristics such electric field distribution thermal stability compared analyzed through overvoltage simulation. design method was presented, performed using materials. temperature profiles also a finite element To analyze performance cable, it simulated with PSCAD/EMTDC program. Based simulation results, analyzed. Results showed that in case cables, properties excellent, but conductivity relatively low; therefore, countermeasures needed.
منابع مشابه
A Methodology for the Assessment of Hvdc-xlpe Cable Insulation
The purpose of this work is to present and to discuss a methodology for the assessment of materials intended to HVDC-XLPE cables, particularly as regards the evaluation of the effects of material formulation on space charge accumulation within the insulation. Sample design, testing method and protocol and criteria used for the material evaluation are specifically considered. It will be shown th...
متن کاملHigh Frequency Characteristics of Medium Voltage XLPE Power Cables
The response of a cable can be used to analyze the variation of the material characteristics along its length. For diagnosis of possible ageing, it is necessary to know how cable design, material properties and cable insulation ageing affects the wave propagation. A cable model has therefore been worked out based upon the high frequency properties of the cable insulation and conductor systems. ...
متن کاملa comparative analysis of the marginal microleakages of two pit and fissure sealans, conseal-f and conseal clear
چکیده ندارد.
15 صفحه اولOn-line time domain reflectometry diagnostics of medium voltage XLPE power cables
Degradation of XLPE insulated power cables by water-trees is a primary cause of failure of these cables. The detection of water-trees and information about the severity of the degradation can be obtained with off-line measurement using dielectric spectroscopy. In many situations only a limited part of the cable may be degraded by the water-trees. In such a situation a method for localization of...
متن کاملa comparative pragmatic analysis of the speech act of “disagreement” across english and persian
the speech act of disagreement has been one of the speech acts that has received the least attention in the field of pragmatics. this study investigates the ways power relations, social distance, formality of the context, gender, and language proficiency (for efl learners) influence disagreement and politeness strategies. the participants of the study were 200 male and female native persian s...
15 صفحه اولذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Energies
سال: 2022
ISSN: ['1996-1073']
DOI: https://doi.org/10.3390/en16010167