Combining direct ground cooling with ground-source heat pumps and district heating: Borehole sizing and land area requirements
نویسندگان
چکیده
This article studies the potential combination of direct ground cooling (DGC) with district heating (DH) and source heat pumps (GSHP) to compare required borehole depths needed drilling areas. It also examines two different sizing approaches optimize investment costs The results show that in most cases are shorter for DGC DH than GSHP combination. is demonstrated optimal range outlet temperatures could be chosen based on trade-off between installation terminal units’ costs.
منابع مشابه
Cooling and Heating with Ground Source Energy
In the recent attempts to stimulate alternative energy sources for heating and cooling of buildings, emphasis has been put on utilisation of the ambient energy from ground source and other renewable energy sources. Exploitation of renewable energy sources and particularly ground heat in buildings can significantly contribute towards reducing dependency on fossil fuels. This paper highlights the...
متن کاملHeat exchanger technology and applications: ground source heat pump system for buildings heating and cooling
The earth’s surface acts as a huge solar collector, absorbing radiation from the sun. In the UK, the ground maintains a constant temperature of 11-13oC several metres below the surface all the year around.1 Among many other alternative energy resources and new potential technologies, the ground source heat pumps (GSHPs) are receiving increasing interest because of their potential to reduce prim...
متن کاملCurrent status of ground source heat pumps in Europe
Geothermal Heat Pumps, or Ground Source Heat Pumps (GSHP), are systems combining a heat pump with a ground heat exchanger (closed loop systems), or fed by ground water from a well (open loop systems). They use the earth as a heat source when operating in heating mode, with a fluid (usually water or a water-antifreeze-mixture) as the media transferring the heat from the earth to the evaporator o...
متن کاملOn the Design and Response of Domestic Ground-Source Heat Pumps in the UK
The design and response of ground source heat pumps coupled to vertical closed loop arrays in UK domestic applications are investigated in this article. Two typical UK house types are selected as the vehicle for the study and a detailed dynamic thermal modelling method is used to arrive at time-series heating demands for the two houses. A new empirical heat pump model is derived using experimen...