Coincidence velocity map imaging using a single detector
نویسندگان
چکیده
منابع مشابه
Velocity map photoelectron-photoion coincidence imaging on a single detector.
Here we report on a new simplified setup for velocity map photoelectron-photoion coincidence imaging using only a single particle detector. We show that both photoelectrons and photoions can be extracted toward the same micro-channel-plate delay line detector by fast switching of the high voltages on the ion optics. This single detector setup retains essentially all the features of a standard t...
متن کاملMultispectral imaging using a single bucket detector.
Existing multispectral imagers mostly use available array sensors to separately measure 2D data slices in a 3D spatial-spectral data cube. Thus they suffer from low photon efficiency, limited spectrum range and high cost. To address these issues, we propose to conduct multispectral imaging using a single bucket detector, to take full advantage of its high sensitivity, wide spectrum range, low c...
متن کاملA velocity map imaging study
A study of the photodissociation dynamics of NO2 in the 200–205 nm region using resonance enhanced multiphoton ionization (REMPI) in conjunction with the velocity map imaging technique is presented. We chose this region because it allowed the use of a single laser to photodissociate the NO2 molecule and probe both the O(D2) fragment using (2+1) REMPI via the 3p ′1P1 state at 2× 205.47 nm and th...
متن کاملA velocity map imaging detector with an integrated gas injection system.
We present the design of a velocity map imaging spectrometer where the target gas is injected from a capillary that is integrated in the repeller plate of the ion optics assembly that drives electrons/ions formed by ionization or dissociation to a two-dimensional detector. The geometry of this design allows the use of gas densities in the interaction region that are two to three orders of magni...
متن کاملA new double imaging velocity focusing coincidence experiment: i2PEPICO.
The vacuum ultraviolet (VUV) beamline of the Swiss Light Source has been upgraded after two years of operation. A new, turntable-type monochromator was constructed at the Paul Scherrer Institut, which allows for fast yaw-alignment as well as quick grating change and exchange. In addition to the original imaging photoelectron photoion coincidence endstation (iPEPICO), a second, complementary dou...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Journal of Chemical Physics
سال: 2017
ISSN: 0021-9606,1089-7690
DOI: 10.1063/1.4981917