Clot retraction facilitates clot lysis

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clot retraction facilitates clot lysis.

Platelet facilitation of clot lysis was studied using the dilute clot lysis assay, a standardized assay for fibrinolysis shown to correlate with the development of postoperative deep vein thrombosis. Clots prepared from dilute platelet poor plasma showed prolonged clot lysis when compared with clots prepared in a similar fashion from dilute platelet rich plasma. Since in the presence of platele...

متن کامل

Feasibility of recording clot lysis with the thermometric clot detector.

Currently, the study of fibrinolysis is beset by problems of methodology (1 ). Disadvantages of many of the present methods for measurement of clot lysisincluding lysis time for the dilute blood clot, thromboelastography, euglobulin clot lysis, fibrin plate method, and caseinolytic assay (1 )-are imprecision of results and time required to perform the test (2). The electromechanical lysis timer...

متن کامل

Kinetics of fibrin clot lysis.

The principles relating the lysis times of fibrin clots to their contents of fibrin, plasminogen and plasminogen-activator were investigated. Mathematical considerations suggested that the square of the lysis time should correlate linearly with the fibrin content, and inversely with the activator and the plasminogen contents of the system. Experimental studies, during which these parameters wer...

متن کامل

Inhibition of Clot Lysis and Decreased Binding of Tissue-Type Plasminogen Activator as a Consequence of Clot Retraction

Tissue-type plasminogen activator (t-PA) is less active in vivo and in vitro against clots that are enriched in platelets, even at therapeutic concentrations. The release of radioactivity from ‘El-fibrin-labeled clots was decreased by 47% 6 hours after the addition of t-PA 400 U/mL when formed in plateletrich versus platelet-poor plasma. This difference was not due to the release of plasminogen...

متن کامل

A new device for measurement of fibrin clot lysis: application to the Euglobulin Clot Lysis Time

BACKGROUND Determination of clot lysis times on whole blood, diluted whole blood, plasma or plasma fraction has been used for many years to assess the overall activity of the fibrinolytic system. We designed a completely computerised semi-automatic 8-channel device for measurement and determination of fibrin clot lysis. The lysis time is evaluated by a mathematical analysis of the lysis curve a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Blood

سال: 1981

ISSN: 0006-4971,1528-0020

DOI: 10.1182/blood.v57.1.44.44