Closed Endotracheal Suctioning Impact on Ventilator-Related Parameters in Obstructive and Restrictive Respiratory Systems: A Bench Study
نویسندگان
چکیده
منابع مشابه
The impact of closed endotracheal suctioning systems on mechanical ventilator performance.
BACKGROUND Closed endotracheal suctioning during mechanical ventilation is increasingly used, but its impact on ventilator function has not been fully studied. METHODS We evaluated the impact of closed suctioning with 11 critical-care ventilators, during assisted ventilation in pressure-support mode, pressure-assist/control mode, volume-assist/control mode, and during continuous positive airw...
متن کاملThe effect of open and closed endotracheal tube suctioning system on respiratory parameters of infants undergoing mechanical ventilation
AIMS Mechanical ventilation is used for some infants in neonatal intensive care units (NICU) due to many physiological and clinical causes. Since these patients have endotracheal tubes, cleaning and keeping the airways open through suctioning should be done to increase oxygenation. This study aimed to evaluate effect of open and closed suctioning methods on respiratory parameters of infants und...
متن کاملthe effect of open and closed endotracheal tube suctioning system on respiratory parameters of infants undergoing mechanical ventilation
background : mechanical ventilation is used for some infants in neonatal intensive care units (nicu) due to many physiological and clinical causes. since these patients have endotracheal tubes, cleaning and keeping the airways open through suctioning should be done to increase oxygenation. this study aimed to evaluate effect of open and closed suctioning methods on respiratory parameters of inf...
متن کاملVentilator-Associated Pneumonia in Patients Admitted to Intensive Care Units, Using Open or Closed Endotracheal Suctioning
BACKGROUND Critically ill patients under mechanical ventilation require frequent suctioning of airway secretion. Closed suction permits suctioning without disconnection from ventilator; so it might decrease hypoxemia and infection rate. OBJECTIVES This study aimed to evaluate the effect of closed tracheal suction system (CTSS) versus open tracheal suction system (OTSS). PATIENTS AND METHODS...
متن کاملPrevention of suctioning-related arterial oxygen desaturation. Comparison of off-ventilator and on-ventilator suctioning.
The purpose of this study was to determine the frequency and severity of arterial oxygen desaturation during and after endotracheal suctioning in a group of ventilator-dependent patients with acute respiratory failure (the majority of whom had underlying obstructive lung disease) and to evaluate the efficacy of several maneuvers designed to minimize desaturation. The adaptor method presented ob...