Detection and quantitation of intermittent CSF rhinorrhea during prolonged cisternography with 111In-DTPA.
In an attempt to improve the diagnosis and to assess the intensity of intermittent cerebrospinal fluid rhinorrhea, indium-111 uptake by nasal pledgets during prolonged cisternography using 111In-DTPA was determined. In 12 patients having suspected cerebrospinal fluid rhinorrhea, cisternograms with calculation of counts/pixel in regions of interest were obtained, blood samples drawn, and nasal p...
متن کامل111In-DTPA Cisternography with SPECT/CT for the Evaluation of Normal Pressure Hydrocephalus
Although new MR imaging techniques can provide highresolution information on CSF dynamics and are not associated with ionizing radiation, SPECT/CT cisternography is a valuable alternative for those with contraindications to MR imaging. SPECT/CT cisternography combines functional and anatomic imaging to provide accurate and detailed information on CSF distribution to be used in conjunction with ...
متن کاملProgressive supranuclear palsy and In111-DTPA cisternography.
Three cases of progressive supranuclear palsy are reported in which In111-DTPA cisternography showed slow diffusion, ventricular reflux and failure of isotope clearance. The clinical diagnosis of progressive supranuclear palsy was confirmed histologically in two of these patients. The possible causes of the cisternographic changes and their relationship to the changes of CSF dynamics in progres...
متن کاملStraightforward thiol-mediated protein labelling with DTPA: Synthesis of a highly active 111In-annexin A5-DTPA tracer
BACKGROUND Annexin A5 (anxA5) has been found useful for molecular imaging of apoptosis and other biological processes. METHODS Here, we report an optimised two-step synthesis of annexin A5-diethylene triamine pentaacetic acid (DTPA) (anxA5-DTPA) for positron emission tomography (PET) and single-photon emission computed tomography (SPECT) imaging with a single purification step. The use of a r...
متن کامل¹¹¹In-DTPA cisternography with SPECT/CT for the evaluation of normal pressure hydrocephalus.
Although new MR imaging techniques can provide high-resolution information on CSF dynamics and are not associated with ionizing radiation, SPECT/CT cisternography is a valuable alternative for those with contraindications to MR imaging. SPECT/CT cisternography combines functional and anatomic imaging to provide accurate and detailed information on CSF distribution to be used in conjunction with...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: RADIOISOTOPES
سال: 1977
ISSN: 1884-4111,0033-8303
DOI: 10.3769/radioisotopes.26.3_185