Charge-coupled device observations of V388 Cyg
نویسندگان
چکیده
منابع مشابه
Charge-coupled device area x-ray detectors
Charge-coupled device ~CCD! area x-ray detector technology is reviewed. CCD detectors consist of a serial chain of signal components, such as phosphors, fiber optics or lenses, image intensifiers and the CCD which serve to convert the x-ray energy to light or electron-hole pairs and to record the spatially resolved image. The various combinations of components that have been used to make CCD de...
متن کاملCharge-Coupled Device Photometry of Comet P/Halley
Comet P/Halley has been observed during its approach to perihelion at heliocentric distances R = I 1.0 AU and R = 8.2 AU. No extended coma is seen and limits can be placed on the fraction of the total light contributed by coma. The brightness of the comet varies on a short time scale. The variations may be due to transient activity or to rotation of the irregular nucleus. ,. 1984 Academic Pre',...
متن کاملA fast, direct x-ray detection charge-coupled device.
A charge-coupled device (CCD) capable of 200 Mpixels/s readout has been designed and fabricated on thick, high-resistivity silicon. The CCDs, up to 600 microm thick, are fully depleted, ensuring good infrared to x-ray detection efficiency, together with a small point spread function. High readout speed, with good analog performance, is obtained by the use of a large number of parallel output po...
متن کاملCalibration procedures for charge-coupled device x-ray detectors
Calibration procedures are described for use with electronic x-ray detectors, with an emphasis on detectors based on fiber-optically coupled charge-coupled devices. Methods are detailed for removing spurious events, pixel pedestals, dark-current, spatial distortion, and intensity response variations for both small-angle and wide-angle applications. The accuracy of the calibration procedures is ...
متن کاملAn approximate two-dimensional transient analysis of charge transport in a buried-channel charge-coupled device
2014 A method for the approximate transient analysis of the BCCD is presented. The solution is obtained by considering only the nearly-linear Poisson/Laplace’s equation in a completelydepleted/charge-neutral region and subsequent estimate of carrier flow across the interface between the charged and neutral regions. Additional factors are introduced in the solution of the equations to ensure tha...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Monthly Notices of the Royal Astronomical Society
سال: 2001
ISSN: 0035-8711,1365-2966
DOI: 10.1046/j.1365-8711.2001.04484.x