Cation disorder in CZTS materials from anomalous diffraction at KMC-2 (BESSY)
نویسندگان
چکیده
منابع مشابه
KMC-1: a high resolution and high flux soft x-ray beamline at BESSY.
The crystal monochromator beamline KMC-1 at a BESSY II bending magnet covers the energy range from soft (1.7 keV) to hard x-rays (12 keV) employing the (n,-n) double crystal arrangement with constant beam offset. The monochromator is equipped with three sets of crystals, InSb, Si (111), and Si (422) which are exchangeable in situ within a few minutes. Beamline and monochromator have been optimi...
متن کاملDiffraction from Materials
Diffraction describes the perturbation of the propagation of wave motion when the wave encounters an object with different properties from the medium in which the wave is normally propagating. It is a subset of the more general phenomenon of scattering, for example the scattering of accelerated subatomic particles by nuclei that is explored by nuclear physicists or the scattering of visible lig...
متن کاملThe at-wavelength metrology facility for UV- and XUV-reflection and diffraction optics at BESSY-II
A technology center for the production of high-precision reflection gratings has been established. Within this project a new optics beamline and a versatile reflectometer for at-wavelength characterization of UV- and XUV-reflection gratings and other (nano-) optical elements has been set up at BESSY-II. The Plane Grating Monochromator beamline operated in collimated light (c-PGM) is equipped wi...
متن کاملThe new HMI beamline MAGS: an instrument for hard X-ray diffraction at BESSY.
The Hahn-Meitner-Institute Berlin is operating the new hard X-ray diffraction beamline MAGS at the Berlin synchrotron radiation source BESSY. The beamline is intended to complement the existing neutron instrumentation at the Berlin Neutron Scattering Centre. The new beamline uses a 7 T multipole wiggler to produce photon fluxes in the 10(11)-10(12) photons s(-1) (100 mA)(-1) (0.1% bandwidth)(-1...
متن کاملSuccesses rate of endoscopic dacryocystorhinostomy at KMC.
BACKGROUND Nasolacrimal duct obstruction is a common problem which can be corrected by dacryocystorhinostomy (DCR). The gold standard treatment for this is DCR operation through an external approach. Development of endoscopic sinus surgery and endoscopic DCR performed through intranasal route is a major recent development in this field. OBJECTIVES The aim of this study is to find out the succ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Acta Crystallographica Section A Foundations and Advances
سال: 2014
ISSN: 2053-2733
DOI: 10.1107/s2053273314082254