Cathode ray polarography and differential pulse polarography of the catalytic molybdenum(VI) wave

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reverse Differential Pulse Voltammetry and Polarography

In this paper we obtain the analytical solution for the reverse Werential pulse O P ) technique for a slow electronic transfer process, starting fkom expressions obtained previously for the faradaic response to a triple potential pulse. The solutions are valid for the planar approximations of a static mercury drop electrode and of a dropping mercury electrode. An irreversible reduction process ...

متن کامل

Differential pulse polarography of the catalytic waves in serum from patients with urological cancers.

Catalytic waves obtained from the perchloric acid-soluble fraction of serum in the presence of hexaminecobalt trichloride appear to conform to a Langmuir adsorption isotherm. Wave heights for sera from patients with untreated urological cancers significantly exceed those from normal subjects. In general, treatment with diethylstilbestrol decreased the wave height. Effects of some other chemothe...

متن کامل

Trace Determination of Azathioprine by Differential Pulse Polarography

A simple and rapid differential pulse polarographic method was developed for the trace determination of azathioprine. A welldefined polarogram with three peaks was obtained in acetate buffer (pH 5.0) with peak potentials -0.27 V, -0.73 V and -1.02 V. The current-concentration linearity was found extend up to 5 x 10 mol L (r = 0.9992) with minimum detection limit of 2.8x10 mol L. The values of r...

متن کامل

Indirect determination of thallium by differential-pulse polarography.

The method is based on the separation of Tl(I) as Tl(2)HPMo(12)O(40), stripping of the molybdate, and measurement of the peak current in differential-pulse polarography of the molybdenum. The calibration graph is linear over the range 2-12 ppm of thallium. The relative standard deviation is 1.2% (7 replicates each containing 500 microg of thallium). The current due to reduction of the molybdenu...

متن کامل

Estimation of Tegaserod Maleate by Differential Pulse Polarography

A highly sensitive differential pulse polarographic method has been developed for the estimation of tegaserod maleate after treating it with hydrogen peroxide solution. The oxidation of tegaserod maleate is a reversible process as the oxidized product could be reduced at hanging mercury drop electrode in a quantitative manner using differential pulse polarography mode. The limit of quantificati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Analytica Chimica Acta

سال: 1979

ISSN: 0003-2670

DOI: 10.1016/s0003-2670(01)93050-8