Calorimetric Behaviour of Electric Cables
نویسندگان
چکیده
A routine cone calorimeter procedure, the theoretical analysis method, based on a set of ignitability data from calorimeter, has been performed. The five sets ignition times at different irradiance levels were used for obtaining experimental needed analysis. tests performed with horizontal specimens size 100 mm × consisting eight pieces commercial poly(vinyl chloride) coaxial power cable. Specimen combustion was carried out under external heat flux constant values equal to 10, 20, 30, 40 and 50 kW·m?2, respectively. Standard fire parameters time results indicate that each parameter, rising trend an increase in radiant observed. It shown use chloride)-based cables is potential safety hazard due emission large amount acid smoke. Quintiere’s theory as useful tool modelling by using small-scale rather than geometrical scale cable experiments. Large test (EN 50399) are also presented compared data.
منابع مشابه
Electric Field Investigation in MV PILC Cables with Void Defect
Abstract—Worldwide, most PILC MV underground cables in use are approaching the end of their design life; hence, failures are likely to increase. This paper studies the electric field and potential distributions within the PILC insulted cable containing common void-defect. The finite element model of the performance of the belted PILC MV underground cable is presented. The variation of the elect...
متن کاملActive tensegrity structures with sliding cables – static and dynamic behaviour
Tensegrities are spatial, reticulated and lightweight structures that are increasingly investigated as structural solutions for active and deployable structures. Tensegrity systems are composed only of axially loaded elements providing opportunities for actuation and deployment through changing element lengths. In cable-based actuation strategies, the deficiency of having to control too many ca...
متن کاملThe Main Cables – Catenary Cables
Thus far, the main cables have been referred to as catenary cables. For a cable to assume the shape of a catenary, the load on the cable must be uniformly distributed. Under the spaced suspender loading, the shape is closer to a parabola. The difference between the two is very slight. Since the equation for a parabola is easier to work with, most engineers use the parabola equation in the desig...
متن کاملUnderstanding charging behaviour of electric vehicle users
We examined the psychological dynamics underlying charging behaviour of electric vehicle (EV) users. Data from 79 EV users were assessed in a 6-month EV field study. On average, users charged their EV three times per week, drove 38 km per day, and they typically had a large surplus of energy remaining upon recharging. Based on first findings concerning charging style among mobile phone users, w...
متن کاملDiagnostics of Electric Cables in Nuclear Power Plants via Joint Time-Frequency Domain Reflectometry
Defective cables in the electric power systems of nuclear power plants can cause a component to fail, resulting in potential safety concerns. Due to this problem, a non-destructive, non-intrusive condition assessment technique is highly desirable. Joint time-frequency domain reflectometry (JTFDR) is proposed and verified to be effective for cross-linked polyethylene (XLPE) cable, which serves c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Energies
سال: 2021
ISSN: ['1996-1073']
DOI: https://doi.org/10.3390/en14041007