Calibration of a Condensation Particle Counter Using a NIST Traceable Method
نویسندگان
چکیده
منابع مشابه
Nist Traceable Radon Calibration System for Calibrating
The NIST (National Institute of Standards and Technology) has recently made available 222Rn emanation standards for test and evaluation. The NIST certified parameters include the ^ ~ a strength and the emanation coefficient. When such a source is loaded into a radon leak tight enclosure of a known volume, 222~n accumulates over time and it is possible to calculate precisely the time integrated ...
متن کاملA Technique for Force Calibration MEMS Traceable to NIST Standards
Characterizing the mechanical properties of materials and biological systems at the nanoscale requires accurate measurement of forces on the order of 10’s of μN and less. Many times custom fabricated MEMS actuators and load cells are employed to apply these forces. Force response of these devices may be very different from their anticipated response due to fabrication induced effects. This make...
متن کاملDevelopment of a New NIST Calibration Service Using the Comparison Method for Vacuum
Influencing the "injection barriers" into prototype molecular wires through metal-molecule Context: Many NIST customers using our vacuum calibration services spanning the pressure range from 0.65 Pa to 133 kPa (5 millitorr to 1000 torr) desire direct traceability to NIST but cannot justify the cost of calibration against relative to the NIST NIST Ultrasonic Interferometer Manometers (UIMs). The...
متن کاملNIST Calibration of a Neutron Spectrometer ROSPEC
A neutron spectrometer was acquired for use in the measurement of National Institute of Standards and Technology neutron fields. The spectrometer included options for the measurement of low and high energy neutrons, for a total measurement range from 0.01 eV up to 17 MeV. The spectrometer was evaluated in calibration fields and was used to determine the neutron spectrum of an Americium-Berylliu...
متن کاملA method for range calculation of proton in liquid water: Validation study using Monte Carlo method and NIST data
Introduction: The main advantage of using ion beams over photons in radiotherapy is due to their inverse depth-dose profiles, allowing higher doses to tumors, while better sparing normal tissues. When calculating dose distributions with ion beams, one crucial point is the uncertainty of the Bragg-peak range. Recently great effort is devoted to enhance the accuracy of the comput...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Aerosol Science and Technology
سال: 2009
ISSN: 0278-6826,1521-7388
DOI: 10.1080/02786820802716735