Bridge Deck Slab with Steel Sheeting and Shear Connectors Subjected to Vertical Loading
نویسندگان
چکیده
منابع مشابه
Testing and numerical modelling of Steel-Concrete-Steel with stud bolts connectors subject to push-out loading
Steel-concrete-steel (SCS) sandwich panels are composed of two steel plates with low thicknesses and high densities and strengths and one thick layer between both plates with low strength and density known as core that is composed of concrete. Cohesive material-epoxy resin or shear connectors are usually used to connect the plates to the concrete core. SCS sandwich composites are being develope...
متن کاملStructural Performance of Steel Pile Caps Strengthened with Perfobond Shear Connectors under Lateral Loading
The conventional strengthening strategy on the connection between the steel pile cap and reinforced concrete footing requires a series of complicated processes such as the distribution of reinforcing bars, their anchorage into concrete, and the usage of shear keys. This study investigates the structural performance of steel pile caps strengthened with newly proposed perfobond shear connectors s...
متن کاملReinforced Concrete Bridge Piers Subjected to Reversed Cyclic Loading
Sixteen large-scale reinforced concrete specimens without web reinforcements were tested to study the behavior of typical bridge piers subjected to deflection reversals that were large enough to cause extensive yielding of the longitudinal reinforcement. The different parameters considered included shear spanto-depth ratio, percentage of longitudinal reinforcement, frequency of the applied load...
متن کاملNumerical and Experimental Investigations on the Behavior of Steel-reinforced Concrete Columns Subjected to Eccentric Loading
Steel-reinforced concrete (SRC) columns, which are classified as composite columns, became the most widely used in recent years; because of their extensive advantages over the reinforced concrete and the steel columns. In this paper, the ductility index and its influential factors were explored to investigate the behavior of SRC columns. A straightforward approach was then proposed by establish...
متن کاملBehaviour of Corroded Stud Shear Connectors under Fatigue Loading
Experimental investigation was conducted on corroded composite push-out specimens to study the behavior of shear studs subjected to fatigue loading. A total of eight standard EC4 push-out specimens were tested. The expected corrosion rate of test specimens ranged from 0 to 50%. The main purpose of these tests was to determine the fatigue life and the reduction effect caused by the corrosion on ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: DEStech Transactions on Materials Science and Engineering
سال: 2017
ISSN: 2572-889X
DOI: 10.12783/dtmse/ictim2017/9948